Evidence map›Paper›PMID 38575859›Full record

ArticleBMC gastroenterology2024

London Protocol under water-perfused HRM in a healthy population, towards novel 3D manometric parameters in an evaluation of anorectal functional disorders.

Alexandre Anefalos, Carlos Augusto Real Martinez, Claudio Saddy Rodrigues Coy

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in BMC gastroenterology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Alexandre AnefalosDepartment of Surgery, FCM, State University of Campinas-UNICAMP, Campinas, SP, Brazil. alex.anefal@cefidi.com.br.ORCID http://orcid.org/0000-0002-7274-4792
Carlos Augusto Real MartinezDepartment of Surgery, FCM, State University of Campinas-UNICAMP, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0001-8088-427X
Claudio Saddy Rodrigues CoyDepartment of Surgery, FCM, State University of Campinas-UNICAMP, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0002-0916-4138
Universidade Estadual de Campinas (UNICAMP) · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimLondon Protocol (LP) and Classification allied to high-resolution manometry (HRM) technological evolution has updated and enhanced the diagnostic armamentarium in anorectal disorders. This study aims to evaluate LP reproducibility under water-perfused HRM, provide normal data and new parameters based on 3D and healthy comparison studies under perfusional HRM.

methodsFifty healthy (25 F) underwent water-perfused 36 channel HRM based on LP at resting, squeeze, cough, push, and rectal sensory. Additional 3D manometric parameters were: pressure-volume (PV) 10

resultsNo difference to genders: resting (LP, CP, and 3D); short squeeze (highest pressure asymmetry); endurance (CP); cough (CP, highest and lowest pressure asymmetry); push (gradient pressure); rectal sensory. Higher pressure in men: short squeeze (maximum incremental, absolute, and mean pressure, PV, lowest pressure asymmetry); long squeeze (PV); cough (anal canal and rectum maximum pressure, anal canal PV); push (anal canal and rectum maximum pressure). Anal canal relaxation was higher in women (push).

conclusionsLP reproducibility is feasible under water-perfused HRM, and comparative studies could bring similarity to dataset expansion. Novel 3D parameters need further studies with healthy and larger data to be validated and for disease comparisons. KEY POINTS: • London Protocol and Classification allied with the technological evolution of HRM (software and probes) has refined the diagnostic armamentarium in anorectal disorders. • Novel 3D and deepening the analysis of manometric parameters before the London Classification as a contributory diagnostic tool. • Comparison of healthy volunteers according to the London Protocol under a perfusional high-resolution system could establish equivalence points.

Indexed as

Fecal IncontinenceRectal DiseasesAnal CanalCoughFemaleHumansLondonMaleManometryPressureRectumReproducibility of Results3D high-resolution manometryAnorectumHealthy volunteersHigh-resolution manometry (HRM)Water-perfused