Evidence map›Paper›PMID 38573892›Full record

ArticlePloS one2024

Evaluation of microbial occurrence in reusable robotic instruments for minimally invasive surgery: A pilot study.

Roy J Pelzer, Wil C van der Zwet, Mike M E G Eggen, Ashley Beard, Paul H M Savelkoul, Jeanne A M C Dirks

Abstract read
In one paragraph

Article in PloS one, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Roy J PelzerDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.
Wil C van der ZwetDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.
Mike M E G EggenDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.
Ashley BeardDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.
Paul H M SavelkoulDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.
Jeanne A M C DirksDepartment of Medical Microbiology, Maastricht University Medical Center, and Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, The Netherlands.ORCID 0000-0002-1961-9589

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In recent decades, minimally invasive surgery has become the favoured surgical technique, with increasing utilisation of robotic surgery to enhance patient outcomes. However, the design complexity of surgical robotic instruments can pose challenges in maintaining adequate cleaning, disinfection and sterilisation-particularly of the device's interior. In our hospital, robotic instruments are reused for a maximum of ten successive patients, following the manufacturer's guidelines. To the best of our knowledge, neither the manufacturer nor ISO standards have specified any methods to determine the sterility of robotic instruments after cleaning, disinfection and sterilisation procedures. In a small pilot study, we used a locally developed protocol to evaluate the sterility of 20 da Vinci SI robotic instruments, with the aim of determining whether the recommended cleaning, disinfection and sterilisation process is adequate to achieve safe usage in subsequent patients. None of the 20 instruments showed viable micro-organisms, therefore the robotic instruments were considered sterile, and suitable for re-use. We recommend our protocol to other hospitals, to be used as an essential control element in the assessment of their unique reprocessing technique for robotic instruments.

Indexed as

InfertilityRobotic Surgical ProceduresDisinfectionHumansMinimally Invasive Surgical ProceduresPilot Projects

Identifiers

PMID38573892
PMCPMC10994333

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.