ArticlePhysical and engineering sciences in medicine2024
A low-cost phantom design for evaluating spine SABR calculations in the presence of prosthetic vertebral stabilization.
Article in Physical and engineering sciences in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Dose-perturbation characteristics are important to consider during the calculation of radiation therapy protocols for patients who are going to receive high doses that would reach the tolerance limits of the spinal cord [1]. Several studies have investigated dose perturbations introduced by metal implants in close proximity to spine SABR treatments [2-7]. However, there is a lack of work assessing this effect using the RayStation TPS [8]. We present an initial design for a low-cost phantom to evaluate spine stereotactic ablative radiotherapy (SABR) in the presence of prosthetic vertebral stabilization. The phantom is modular, allowing the prosthetic at the centre of the phantom to be removed by exchanging the central block. It also includes space to insert ion chamber and film. The agreement of the RayStation TPS (v8.0B) collapsed cone convolution (CCC) calculation and measurement was determined for phantom versions with and without prosthetic. There was little to no change in the agreement between the measured and calculated dose when introducing metallic hardware. This suggests that our Raystation-based SABR planning approach for patients with spinal hardware meets clinical expectations. Departments without access to anthropomorphic phantoms may find this design useful but should test their phantom design in typical clinical settings to ensure it is robust to real world situations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials