Evidence map›Paper›PMID 38572168›Full record

ArticleComputational and structural biotechnology journal2024

LiViT-Net: A U-Net-like, lightweight Transformer network for retinal vessel segmentation.

Le Tong, Tianjiu Li, Qian Zhang, Qin Zhang, Renchaoli Zhu, Wei Du, Pengwei Hu

Abstract read
In one paragraph

Article in Computational and structural biotechnology journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Benchmarking Vision Encoders for Image Classification in Ophthalmology.Computational and structural biotechnology journal · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Le TongThe College of Information, Mechanical and Electrical Engineering, Shanghai Normal University, No. 100 Haisi Road, Shanghai, 201418, China.
Tianjiu LiThe College of Information, Mechanical and Electrical Engineering, Shanghai Normal University, No. 100 Haisi Road, Shanghai, 201418, China.
Qian ZhangThe College of Information, Mechanical and Electrical Engineering, Shanghai Normal University, No. 100 Haisi Road, Shanghai, 201418, China.
Qin ZhangOphthalmology Department, Jing'an District Central Hospital, No. 259, Xikang Road, Shanghai, 200040, China.
Renchaoli ZhuThe College of Information, Mechanical and Electrical Engineering, Shanghai Normal University, No. 100 Haisi Road, Shanghai, 201418, China.
Wei DuLaboratory of Smart Manufacturing in Energy Chemical Process, East China University of Science and Technology, No. 130 Meilong Road, Shanghai, 200237, China.
Pengwei HuThe Xinjiang Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, 40-1 South Beijing Road, Urumqi, 830011, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The intricate task of precisely segmenting retinal vessels from images, which is critical for diagnosing various eye diseases, presents significant challenges for models due to factors such as scale variation, complex anatomical patterns, low contrast, and limitations in training data. Building on these challenges, we offer novel contributions spanning model architecture, loss function design, robustness, and real-time efficacy. To comprehensively address these challenges, a new U-Net-like, lightweight Transformer network for retinal vessel segmentation is presented. By integrating MobileViT+ and a novel local representation in the encoder, our design emphasizes lightweight processing while capturing intricate image structures, enhancing vessel edge precision. A novel joint loss is designed, leveraging the characteristics of weighted cross-entropy and Dice loss to effectively guide the model through the task's challenges, such as foreground-background imbalance and intricate vascular structures. Exhaustive experiments were performed on three prominent retinal image databases. The results underscore the robustness and generalizability of the proposed LiViT-Net, which outperforms other methods in complex scenarios, especially in intricate environments with fine vessels or vessel edges. Importantly, optimized for efficiency, LiViT-Net excels on devices with constrained computational power, as evidenced by its fast performance. To demonstrate the model proposed in this study, a freely accessible and interactive website was established (https://hz-t3.matpool.com:28765?token=aQjYR4hqMI), revealing real-time performance with no login requirements.

Indexed as

Joint lossLightweightRetinal vessel segmentationTransformer

Identifiers

PMID38572168
PMCPMC10987887

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.