ArticleMedical physics2024
Estimate and compensate head motion in non-contrast head CT scans using partial angle reconstruction and deep learning.
Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Diffusion Model-Based Motion Correction in Portable Computed Tomography for Brain: A Human Observer Study.Academic radiology · 2026Article
- Clinical applications of portable CT scanners.The British journal of radiology · 2025Review
- Portable head CT motion artifact correction via diffusion-based generative model.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2025Article
- Head CT Scan Motion Artifact Correction via Diffusion-Based Generative Models.Applications of medical artificial intelligence : third international workshop, AMAI 2024, held in conjunction with MICCAI 2024, Marrakesh, Morocco, October 6, 2024 : proceedings. AMAI (Workshop) (3rd : 2024 : Marrakech, Morocco) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundPatient head motion is a common source of image artifacts in computed tomography (CT) of the head, leading to degraded image quality and potentially incorrect diagnoses. The partial angle reconstruction (PAR) means dividing the CT projection into several consecutive angular segments and reconstructing each segment individually. Although motion estimation and compensation using PAR has been developed and investigated in cardiac CT scans, its potential for reducing motion artifacts in head CT scans remains unexplored. PURPOSE: To develop a deep learning (DL) model capable of directly estimating head motion from PAR images of head CT scans and to integrate the estimated motion into an iterative reconstruction process to compensate for the motion.
methodsHead motion is considered as a rigid transformation described by six time-variant variables, including the three variables for translation and three variables for rotation. Each motion variable is modeled using a B-spline defined by five control points (CP) along time. We split the full projections from 360° into 25 consecutive PARs and subsequently input them into a convolutional neural network (CNN) that outputs the estimated CPs for each motion variable. The estimated CPs are used to calculate the object motion in each projection, which are incorporated into the forward and backprojection of an iterative reconstruction algorithm to reconstruct the motion-compensated image. The performance of our DL model is evaluated through both simulation and phantom studies.
resultsThe DL model achieved high accuracy in estimating head motion, as demonstrated in both the simulation study (mean absolute error (MAE) ranging from 0.28 to 0.45 mm or degree across different motion variables) and the phantom study (MAE ranging from 0.40 to 0.48 mm or degree). The resulting motion-corrected image,
conclusionsWe demonstrate that using PAR and our proposed deep learning model enables accurate estimation of patient head motion and effectively reduces motion artifacts in the resulting head CT images.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.