Evidence map›Paper›PMID 38569143›Full record

ArticleMedical physics2024

Estimate and compensate head motion in non-contrast head CT scans using partial angle reconstruction and deep learning.

Zhennong Chen, Quanzheng Li, Dufan Wu

Abstract read
In one paragraph

Article in Medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Clinical applications of portable CT scanners.The British journal of radiology · 2025
    Review
  3. Portable head CT motion artifact correction via diffusion-based generative model.Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society · 2025
    Article
  4. Head CT Scan Motion Artifact Correction via Diffusion-Based Generative Models.Applications of medical artificial intelligence : third international workshop, AMAI 2024, held in conjunction with MICCAI 2024, Marrakesh, Morocco, October 6, 2024 : proceedings. AMAI (Workshop) (3rd : 2024 : Marrakech, Morocco) · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Zhennong ChenCenter for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Quanzheng LiCenter for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.
Dufan WuCenter for Advanced Medical Computing and Analysis, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA.

Funding

Deep learning Based Phenotyping and Treatment Optimization for Heart Failure with Preserved Ejection FractionR01HL159183 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI LI, QUANZHENG · 2022 to 2025
$2.3M
Dual Energy CT-enabled Asymptomatic Pulmonary Embolism Detection on Non-contrast CTR21EB031939 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI WU, DUFAN · 2021 to 2021
$449k
NHLBI NIH HHS R01 HL159183NIBIB NIH HHS R01HL159183NIBIB NIH HHS R21 EB031939NIBIB NIH HHS R21EB031939
6 · The paper itself

Abstract

backgroundPatient head motion is a common source of image artifacts in computed tomography (CT) of the head, leading to degraded image quality and potentially incorrect diagnoses. The partial angle reconstruction (PAR) means dividing the CT projection into several consecutive angular segments and reconstructing each segment individually. Although motion estimation and compensation using PAR has been developed and investigated in cardiac CT scans, its potential for reducing motion artifacts in head CT scans remains unexplored. PURPOSE: To develop a deep learning (DL) model capable of directly estimating head motion from PAR images of head CT scans and to integrate the estimated motion into an iterative reconstruction process to compensate for the motion.

methodsHead motion is considered as a rigid transformation described by six time-variant variables, including the three variables for translation and three variables for rotation. Each motion variable is modeled using a B-spline defined by five control points (CP) along time. We split the full projections from 360° into 25 consecutive PARs and subsequently input them into a convolutional neural network (CNN) that outputs the estimated CPs for each motion variable. The estimated CPs are used to calculate the object motion in each projection, which are incorporated into the forward and backprojection of an iterative reconstruction algorithm to reconstruct the motion-compensated image. The performance of our DL model is evaluated through both simulation and phantom studies.

resultsThe DL model achieved high accuracy in estimating head motion, as demonstrated in both the simulation study (mean absolute error (MAE) ranging from 0.28 to 0.45 mm or degree across different motion variables) and the phantom study (MAE ranging from 0.40 to 0.48 mm or degree). The resulting motion-corrected image,

conclusionsWe demonstrate that using PAR and our proposed deep learning model enables accurate estimation of patient head motion and effectively reduces motion artifacts in the resulting head CT images.

Indexed as

ArtifactsDeep LearningImage Processing, Computer-AssistedTomography, X-Ray ComputedHeadHead MovementsHumansPhantoms, Imagingdeep learninghead CTmotion correctionpartial angle reconstruction

Identifiers

PMID38569143
PMCPMC11128317

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.