Evidence map›Paper›PMID 38567923›Full record

ArticleDental press journal of orthodontics2024

Evaluating the precision and accuracy of digital dental models with a low-cost structured light device.

Vitor de Toledo Stuani, Matheus Dante de Paula, Raphaella Coelho Michel, Gustavo Gonçalves do Prado Manfredi, Edna Maria de Oliveira Fernandes, Diana Gabriela Soares Dos Passos

Open access · diamondAbstract read
In one paragraph

Article in Dental press journal of orthodontics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 96% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Vitor de Toledo StuaniUniversidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos (Bauru/SP, Brazil).ORCID http://orcid.org/0000-0001-5290-7614
Matheus Dante de PaulaUniversidade de São Paulo, Hospital de Reabilitação de Anomalias Craniofaciais (Bauru/SP, Brazil).ORCID http://orcid.org/0009-0004-6112-7897
Raphaella Coelho MichelUniversidade de Saúde e Ecologia Humana, Faculdade de Odontologia, Disciplina de Periodontia (Vespasiano/MG, Brazil).ORCID http://orcid.org/0000-0003-0878-1502
Gustavo Gonçalves do Prado ManfrediUniversidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos (Bauru/SP, Brazil).ORCID http://orcid.org/0000-0001-9623-9769
Edna Maria de Oliveira FernandesUniversidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos (Bauru/SP, Brazil).ORCID http://orcid.org/0009-0001-1858-4257
Diana Gabriela Soares Dos PassosUniversidade de São Paulo, Faculdade de Odontologia de Bauru, Departamento de Dentística, Endodontia e Materiais Odontológicos (Bauru/SP, Brazil).ORCID http://orcid.org/0000-0002-1485-6104
Universidade de São Paulo · BRInstituto de Saúde · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study evaluated the accuracy and precision of digital models acquisition using a home-built, low-cost scanning system based on the structured light method.

methodsa plaster model (PM) was scanned using the experimental device (SL) and a dental desktop scanner (DS). The teeth dimensions of PM and SL models were measured in triplicate, with a caliper and digitally, respectively. The agreement of the measurements of each model was evaluated using the intraclass correlation coefficient, and the validity between the different measurement techniques was assessed using the Bland-Altman analysis. The accuracy and precision of the models were qualitatively investigated using the mesh superposition of the SL and DS models.

resultsA high intraclass correlation coefficient was observed in all models (PM=0.964; SL1=0.998; SL2=0.995; SL3=0.998), and there was no statistical difference between the measurements of the SL models (p>0.05). PM and SL model measurements were found to be in good agreement, with only 3.57% of the observed differences between the same measurement being located outside 95% limits of agreement according to Bland and Altman (0.43 and -0.40 mm). In the superimpositions of SL-SL and SL-DS models, areas of discrepancy greater than 0.5 mm were observed mainly in interproximal, occlusal, and cervical sites.

conclusionThese results indicate that the home-built SL scanning system did not possess sufficient accuracy and precision for many clinical applications. However, the consistency in preserving the dental proportions suggests that the equipment can be used for planning, storage, and simple clinical purposes.

Indexed as

Imaging, Three-DimensionalToothModels, DentalReproducibility of Results

Identifiers

PMID38567923
PMCPMC10983842
OpenAlexW4393324009

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.