Evidence map›Paper›PMID 38567221›Full record

ArticleCureus2024

Correlation Between the Cost and Safety of Corneal Graft Types.

Panagiotis S Kousiouris, Maria Kantzanou, Maria Dantsiou, Amalia Drosopoulou, Konstantinos Rallis, Dimitrios Papakonstantinou, Marilita M Moschos

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 97% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Biomaterials for Corneal Regeneration.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Panagiotis S KousiourisFirst Department of Ophthalmology, National and Kapodistrian University of Athens, Medical School, Athens General Hospital "Georgios Gennimatas", Athens, GRC.
Maria KantzanouDepartment of Hygiene, Epidemiology and Medical Statistics, National and Kapodistrian University of Athens, Medical School, Athens, GRC.
Maria DantsiouDepartment of Purchasing, Athens General Hospital "Georgios Gennimatas", Athens, GRC.
Amalia DrosopoulouFirst Department of Ophthalmology, Athens General Hospital "Georgios Gennimatas", Athens, GRC.
Konstantinos RallisState Department of Ophthalmology, Athens General Hospital "Georgios Gennimatas", Athens, GRC.
Dimitrios PapakonstantinouFirst Department of Ophthalmology, National and Kapodistrian University of Athens, Medical School, Athens, GRC.
Marilita M MoschosFirst Department of Ophthalmology, National and Kapodistrian University of Athens, Athens, GRC.
Piedmont Athens Regional · USAthens State University · USGeneral Hospital of Athens G. Genimatas · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Corneal diseases are the fourth most common cause of blindness worldwide. In the majority of these diseases, vision reduction is reversible and can be restored to a large extent by replacing the cornea through specific surgery and, in particular, transplantation. In Greece, due to a lack of organized eye banks as well as donors, the grafts intended for corneal transplantation usually come from eye banks abroad. This study focuses on the dynamics of cost versus value in the decision-making process for the procurement of corneal grafts, ultimately investigating the safety that the procured grafts provide to patients. Methodology A total of 267 patients with severe vision problems who underwent 301 corneal and amniotic membrane transplants from years 2020 to 2023 at the Transplant Unit of the Athens General Hospital "Georgios Gennimatas" were included in this study. All patients who were deemed appropriate to undergo corneal transplant operations, the diagnosis that led to the specific surgery, and other relevant data were recorded and evaluated. Results There was no significant difference in the ratio between males and females (51.3% male and 48.7% female). The mean age of the patients was 66.5 years (SD = 13.7 years). Graft problems were faced by 13.9% of the patients, with the amniotic membrane by 1.5% (in the total number of surgical operations) and both eyes by 4.5% of patients. The majority of the patients had undergone only one surgery (88.8%). Reoperation was needed in 14% of the cases, and 7.6% of the cases were surgeries that occurred due to graft rejection or non-functioning grafts from surgeries performed at another hospital or clinic. In the majority of surgeries (60.8%), a Descemet's stripping automated endothelial keratoplasty graft was used. The mean cost was 3,167 euro (SD = 960.3 euro). Furthermore, in 35.8% of the surgeries, the graft was preserved with amphotericin. Conclusions The present study draws useful conclusions about the effectiveness of surgical interventions through the correlation of cost and safety of the grafts that are approved and finally used in corneal transplants, as well as the submission of proposals to improve the procedures and lead to patient benefits.

Indexed as

cornea pathologycornea transplantationfuchs endothelial corneal dystrophykeratoconus (kc)public health policy

Identifiers

PMID38567221
PMCPMC10986444
OpenAlexW4392343215

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.