Evidence map›Paper›PMID 38566810›Full record

ArticleStructural dynamics (Melville, N.Y.)2024

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe

Xiaoyi Sun, Joseph Williams, Sachin Sharma, Shriraj Kunjir, Dan Morris, Shen Zhao, Chong-Yu Ruan

Abstract read
In one paragraph

Article in Structural dynamics (Melville, N.Y.), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiaoyi SunDepartment of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.ORCID https://orcid.org/0000-0002-4819-5738
Joseph WilliamsDepartment of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.
Sachin SharmaDepartment of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.ORCID https://orcid.org/0009-0001-6415-379X
Shriraj KunjirFacility for Rare Isotope Beams, Michigan State University, East Lansing, Michigan 48824, USA.ORCID https://orcid.org/0009-0007-4035-6764
Dan MorrisFacility for Rare Isotope Beams, Michigan State University, East Lansing, Michigan 48824, USA.
Shen ZhaoFacility for Rare Isotope Beams, Michigan State University, East Lansing, Michigan 48824, USA.ORCID https://orcid.org/0000-0002-1869-5555
Chong-Yu RuanDepartment of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824, USA.ORCID https://orcid.org/0000-0002-0166-4015

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe

Identifiers

PMID38566810
PMCPMC10987196

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.