Evidence map›Paper›PMID 38564013›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Titanium versus stainless steel alloy bridge plates for distal femur fractures: Does callus form earlier with titanium?

Michael Kutzler, Joseph T Patterson, Hayden Anz, Jacob Siahaan, Stephen J Warner, Joshua L Gary

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Michael KutzlerDepartment of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA.
Joseph T PattersonDepartment of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo St. Suite 2000, Los Angeles, CA, 90033, USA.
Hayden AnzDepartment of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA.
Jacob SiahaanDepartment of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA.
Stephen J WarnerDepartment of Orthopaedic Surgery, University of Texas Health Science Center at Houston, 6400 Fannin St. Suite 1700, Houston, TX, 77030, USA.
Joshua L GaryDepartment of Orthopaedic Surgery, Keck School of Medicine of University of Southern California, 1520 San Pablo St. Suite 2000, Los Angeles, CA, 90033, USA. joshgary14@gmail.com.ORCID http://orcid.org/0000-0002-6326-2468
The University of Texas Health Science Center at Houston · USUniversity of Southern California · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionDistal femur fractures account for 3-6% of all femur fractures. Internal fixation of most distal femur fractures with an anatomic lateral locking plate should permit some motion at the metaphyseal portion of the fracture when secondary bone healing is planned by the operating surgeon. While several studies have been performed evaluating union rates for distal femur fractures with stainless steel and titanium plates, the timing of callus formation between stainless steel and titanium implants used as bridge plates for distal femur fractures (AO/OTA 33-A and -C) has been investigated to a lesser extent. We hypothesize that callus will be visualized earlier with post-operative radiographs with titanium versus stainless steel bridge plates.

methodsWe retrospectively reviewed a consecutive cohort of patients over 18 years of age with acute AO/OTA 33-A and 33-C fracture patterns treated with an isolated stainless steel or titanium lateral bridge plate within 4 weeks of injury by a single fellowship-trained orthopedic trauma surgeon from 2011 to 2020 at one academic Level 1 trauma center. An independent, fellowship-trained orthopedic trauma attending surgeon reviewed anterior-posterior (AP) and lateral radiographs from every available post-operative clinic visit and graded them using the Modified Radiographic Score for Tibia (mRUST).

resultsTwenty-five subjects were included in the study with 10 with stainless steel and 15 with titanium plates. There were no significant differences in demographics between both groups, including age, sex, BMI, injury classification, open versus closed, mechanism, and laterality. Statistically significant increased mRUST scores, indicating increased callus formation, were seen on 12-week radiographs (8.4 vs. 11.9, p = 0.02) when titanium bridge plates were used. There were no statistically significant differences in mRUST scores at 6 or 24-weeks, but scores in the titanium group were higher in at every timepoint. DISCUSSION: In conclusion, we observed greater callus formation at 12 weeks after internal fixation of 33-A and 33-C distal femur fractures treated with titanium locked lateral distal femoral bridge plates compared to stainless steel plates. Our data suggest that titanium metallurgy may have quicker callus formation compared to stainless steel if an isolated, lateral locked bridge plate is chosen for distal femur fracture fixation.

Indexed as

Bone PlatesBony CallusFemoral FracturesFracture Fixation, InternalStainless SteelTitaniumAdultAgedFemaleFemoral Fractures, DistalFracture HealingHumansMaleMiddle AgedRadiographyRetrospective StudiesStainless SteelTitaniumCallusDistal femurFractureStainless steelTitanium

Identifiers

PMID38564013
OpenAlexW4393411341

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.