Evidence map›Paper›PMID 38561788›Full record

ArticleJournal of orthopaedic surgery and research2024

Experimental assessment of pelvis slipping during postless traction for orthopaedic applications.

Marco Daghero, Simone Borrelli, Taian M Vieira, Francesco Cannito, Alessandro Aprato, Andrea Audisio, Cristina Bignardi, Mara Terzini

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Postless versus traditional hip arthroscopy: A multilevel meta-analysis of current evidence on efficacy and safety.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2025
    Pooled it
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Marco DagheroDepartment of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
Simone BorrelliDepartment of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy. simone.borrelli@polito.it.
Taian M VieiraLISiN-Department of Electronics and Telecommunications, Politecnico di Torino, Turin, Italy.
Francesco CannitoDepartment of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
Alessandro ApratoDepartment of Surgical Sciences, University of Turin, Turin, Italy.
Andrea AudisioDepartment of Surgical Sciences, University of Turin, Turin, Italy.
Cristina BignardiDepartment of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
Mara TerziniDepartment of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.

Funding

Ministero dell'Università e della Ricerca PNRR-NGEU (MUR - DM 351/2022)
6 · The paper itself

Abstract

backgroundThe application of lower limb traction during hip arthroscopy and femur fractures osteosynthesis is commonplace in orthopaedic surgeries. Traditional methods utilize a perineal post on a traction table, leading to soft tissue damage and nerve neuropraxia. A postless technique, using high-friction pads, has been considered as a potential damage-free alternative. However, whether these pads sufficiently prevent patient displacement remains unknown. Thus, this study systematically assesses the efficacy of commercial high-friction pads (PinkPad and CarePad) in restraining subject displacement, for progressively increasing traction loads and different Trendelenburg angles.

methodsThree healthy male subjects were recruited and tested in supine and Trendelenburg positions (5° and 10°), using a customized boot-pulley system. Ten load disks (5 kg) were dropped at 15s intervals, increasing gradually the traction load up to 50 kg. Pelvis displacement along the traction direction was measured with a motion capture system. The displacement at 50 kg of traction load was analyzed and compared across various pads and bed inclinations. Response to varying traction loads was statistically assessed with a quadratic function model.

resultsPelvis displacement at 50 kg traction load was below 60 mm for all conditions. Comparing PinkPad and CarePad, no significant differences in displacement were observed. Finally, similar displacements were observed for the supine and Trendelenburg positions.

conclusionsBoth PinkPad and CarePad exhibited nearly linear behavior under increasing traction loads, limiting displacement to 60 mm at most for 50 kg loads. Contrary to expectations, placing subjects in the Trendelenburg position did not increase adhesion.

Indexed as

OrthopedicsFracture Fixation, InternalHip JointHumansMalePelvisTractionCarePadFemur fractureHigh-friction padsHip arthroscopyPinkPadPostless techniquePostless tractionTrendelenburg position

Identifiers

PMID38561788
PMCPMC10983627

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.