Evidence map›Paper›PMID 38561583›Full record

ArticleSurgical endoscopy2024

Using neural networks to autonomously assess adequacy in intraoperative cholangiograms.

Henry Badgery, Yuning Zhou, James Bailey, Peter Brotchie, Lynn Chong, Daniel Croagh, Mark Page, Catherine E Davey, Matthew Read

Open access · hybridAbstract read
In one paragraph

Article in Surgical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Henry BadgeryDepartment of Upper Gastrointestinal Surgery, St Vincent's Hospital Melbourne, Melbourne, Australia. henry.badgery@svha.org.au.ORCID 0000-0003-1528-9268
Yuning ZhouDepartment of Biomedical Engineering, The University of Melbourne, Parkville, Australia.
James BaileySchool of Computing and Information Systems, The University of Melbourne, Parkville, Australia.
Peter BrotchieDepartment of Radiology, St Vincent's Hospital Melbourne, Melbourne, Australia.
Lynn ChongDepartment of Upper Gastrointestinal Surgery, St Vincent's Hospital Melbourne, Melbourne, Australia.
Daniel CroaghDepartment of Upper Gastrointestinal Surgery, St Vincent's Hospital Melbourne, Melbourne, Australia.
Mark PageDepartment of Radiology, St Vincent's Hospital Melbourne, Melbourne, Australia.
Catherine E DaveyDepartment of Biomedical Engineering, The University of Melbourne, Parkville, Australia.
Matthew ReadDepartment of Upper Gastrointestinal Surgery, St Vincent's Hospital Melbourne, Melbourne, Australia.
The University of Melbourne · AUSt Vincent's Hospital Melbourne · AU

Funding

Epworth Foundation 2022
6 · The paper itself

Abstract

backgroundIntraoperative cholangiography (IOC) is a contrast-enhanced X-ray acquired during laparoscopic cholecystectomy. IOC images the biliary tree whereby filling defects, anatomical anomalies and duct injuries can be identified. In Australia, IOC are performed in over 81% of cholecystectomies compared with 20 to 30% internationally (Welfare AIoHa in Australian Atlas of Healthcare Variation, 2017). In this study, we aim to train artificial intelligence (AI) algorithms to interpret anatomy and recognise abnormalities in IOC images. This has potential utility in (a) intraoperative safety mechanisms to limit the risk of missed ductal injury or stone, (b) surgical training and coaching, and (c) auditing of cholangiogram quality. METHODOLOGY: Semantic segmentation masks were applied to a dataset of 1000 cholangiograms with 10 classes. Classes corresponded to anatomy, filling defects and the cholangiogram catheter instrument. Segmentation masks were applied by a surgical trainee and reviewed by a radiologist. Two convolutional neural networks (CNNs), DeeplabV3+ and U-Net, were trained and validated using 900 (90%) labelled frames. Testing was conducted on 100 (10%) hold-out frames. CNN generated segmentation class masks were compared with ground truth segmentation masks to evaluate performance according to a pixel-wise comparison.

resultsThe trained CNNs recognised all classes.. U-Net and DeeplabV3+ achieved a mean F1 of 0.64 and 0.70 respectively in class segmentation, excluding the background class. The presence of individual classes was correctly recognised in over 80% of cases. Given the limited local dataset, these results provide proof of concept in the development of an accurate and clinically useful tool to aid in the interpretation and quality control of intraoperative cholangiograms.

conclusionOur results demonstrate that a CNN can be trained to identify anatomical structures in IOC images. Future performance can be improved with the use of larger, more diverse training datasets. Implementation of this technology may provide cholangiogram quality control and improve intraoperative detection of ductal injuries or ductal injuries.

Indexed as

CholangiographyCholecystectomy, LaparoscopicNeural Networks, ComputerAlgorithmsBile DuctsHumansIntraoperative CareArtificial intelligenceCholangiogramConvolutional neural networkLaparoscopic cholecystectomy

Identifiers

PMID38561583
PMCPMC11078812
OpenAlexW4393374571

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.