Evidence map›Paper›PMID 38559644›Full record

ArticleJournal of International Society of Preventive & Community Dentistry

Comparative Evaluation of Microtensile Bond Strength in Three Different Dentin Luting Agents: An

Leonor Cristina Castro-Ramirez, Marysela Irene Ladera-Castañeda, Hernán Rafael Cachay-Criado, María Isabel Alvino-Vales, Carlos López-Gurreonero, Luis Adolfo Cervantes-Ganoza, César Félix Cayo-Rojas

Abstract read
In one paragraph

Article in Journal of International Society of Preventive & Community Dentistry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Journal of clinical and experimental dentistry · 2025
    Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Leonor Cristina Castro-RamirezUniversidad Privada San Juan Bautista, School of Stomatology, Lima, Peru 15066.
Marysela Irene Ladera-CastañedaUniversidad Nacional Federico Villarreal, Postgraduate School, "Grupo de Investigación Salud y Bienestar Global", Lima, Peru 15084.
Hernán Rafael Cachay-CriadoUniversidad Privada San Juan Bautista, School of Stomatology, Lima, Peru 15066.
María Isabel Alvino-ValesUniversidad Privada San Juan Bautista, School of Stomatology, Lima, Peru 15066.
Carlos López-GurreoneroUniversidad Científica del Sur, School of Stomatology, Lima, Peru 15084.
Luis Adolfo Cervantes-GanozaUniversidad Inca Garcilaso de la Vega, Faculty of Stomatology, Lima, Peru 15084.
César Félix Cayo-RojasUniversidad Privada San Juan Bautista, School of Stomatology, Lima, Peru 15066.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: Long-term clinical success on indirect restorations is largely determined by bonding efficiency of the luting agent, with adhesion to dentin being the main challenge. Therefore, aim of this study was to assess the microtensile bond strength when using flowable resin composite, preheated resin composite and dual self-adhesive resin cement as dentin luting agents. Materials and Methods: Occlusal thirds of molar teeth were cut and randomly divided into 3 groups to be cemented: RelyX™U200, Filtek™ Z250 XT- preheated to 70° and Filtek Flow™ Z350XT. They were then thermocycled 5000 times between 5+/-2°C and 55+/-2°C. Subsequently, 10 microbars per group were prepared. The 30 samples were placed in saline solution for 24 hours at room temperature prior to microtensile test. This was performed with a digital universal testing machine at a crosshead speed of 0.5 mm/min. The bond strength values obtained were analyzed in Megapascals (MPa). Measures of central tendency such mean and measures of dispersion such standard deviation were used. In addition, the Kruskall Wallis non-parametric test with Bonferroni post hoc test was applied, considering a significance value of 5% ( Results: The dentin microtensile bond strengths of preheated resin composite, flowable resin composite and dual self-adhesive cement were 6.08 ± 0.66 Mpa, 5.25 ± 2.60Mpa and 2.82 ± 1.26Mpa, respectively. In addition, the preheated resin composite exhibited significantly higher microtensile bond strength compared to the dual self-adhesive cement ( Conclusions: The microtensile bond strength in dentin was significantly higher when using a preheated resin composite at 70°C as a luting agent compared to dual self-adhesive cement. However, the preheated resin composite showed similar microtensile bond strength compared to the flowable resin composite.

Indexed as

Dentistryflowable resinluting agentmicrotensile bond strengthpreheated resinresin composite

Identifiers

PMID38559644
PMCPMC10980309

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.