ArticleIEEE transactions on medical imaging2024
High-Resolution Power Doppler Using Null Subtraction Imaging.
Article in IEEE transactions on medical imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 27 citations in OpenAlex.
- Differential aperture modulation enables high-fidelity 3D photoacoustic imaging.Photoacoustics · 2026Article
- Contrast-Free Ultrasound Microvascular Imaging via Radiality and Similarity Weighting.IEEE transactions on ultrasonics · 2026Article
- Ultrasound phase microscopy for rapid label-free super-resolution vascular imaging.Research square · 2026Article
- Large elements and advanced beamformers for increased field of view in 2-D ultrasound matrix arrays.ArXiv · 2026Article
- Increasing ultrasound field-of-view with reduced element count arrays containing large elements.ArXiv · 2026Article
- Null subtraction imaging combined with modified delay multiply-and-sum beamforming for coherent plane-wave compounding.Medical & biological engineering & computing · 2025Article
- OptimizingPhysics in medicine and biology · 2025Article
- Velocity-Constraint Kalman Filtering for Enhanced Bubble Tracking in Motion-Compensated Ultrasound Localization Microscopy.Research (Washington, D.C.) · 2025Article
- Article
- Article
- Background Noise Removal in Non-Contrast- Enhanced Ultrasound Microvasculature Imaging Using Combined Collaborative, Morphological, and Vesselness Filtering.IEEE access : practical innovations, open solutions · 2024Article
- High-Level Synthesis Design of Scalable Ultrafast Ultrasound Beamformer With Single FPGA.IEEE transactions on biomedical circuits and systems · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
To improve the spatial resolution of power Doppler (PD) imaging, we explored null subtraction imaging (NSI) as an alternative beamforming technique to delay-and-sum (DAS). NSI is a nonlinear beamforming approach that uses three different apodizations on receive and incoherently sums the beamformed envelopes. NSI uses a null in the beam pattern to improve the lateral resolution, which we apply here for improving PD spatial resolution both with and without contrast microbubbles. In this study, we used NSI with three types of singular value decomposition (SVD)-based clutter filters and noise equalization to generate high-resolution PD images. An element sensitivity correction scheme was also proposed as a crucial component of NSI-based PD imaging. First, a microbubble trace experiment was performed to evaluate the resolution improvement of NSI-based PD over traditional DAS-based PD. Then, both contrast-enhanced and contrast free ultrasound PD images were generated from the scan of a rat brain. The cross-sectional profile of the microbubble traces and microvessels were plotted. FWHM was also estimated to provide a quantitative metric. Furthermore, iso-frequency curves were calculated to provide a resolution evaluation metric over the global field of view. Up to six-fold resolution improvement was demonstrated by the FWHM estimate and four-fold resolution improvement was demonstrated by the iso-frequency curve from the NSI-based PD microvessel images compared to microvessel images generated by traditional DAS-based beamforming. A resolvability of [Formula: see text] was measured from the NSI-based PD microvessel image. The computational cost of NSI-based PD was only increased by 40 percent over the DAS-based PD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.