ArticleFacts, views & vision in ObGyn2024
The first robotic-assisted hysterectomy below the bikini line with the Dexter robotic system™.
Article in Facts, views & vision in ObGyn, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- Emerging robotic platforms in gynecologic surgery: a systematic review.Journal of robotic surgery · 2026Pooled it
- The dexter robotic system in gynecological surgery: preliminary clinical data from routine use.Journal of robotic surgery · 2026Article
- Kurt-Semm-Center of minimally invasive and robot-assisted surgery: Over 10 years of an interdisciplinary and interprofessional project in clinical application, research and training.Journal of robotic surgery · 2026Review
- Implementation of a new robotic system: challenges for the surgical team and ethical concerns about patient safety, a longitudinal questionnaire study.BMJ connections surgery · 2026Article
- Robotic-assisted hysterectomy using DEXTERFacts, views & vision in ObGyn · 2025Article
- IDEAL-compliant implementation of the DexterInnovative surgical sciences · 2025Article
- Multicenter evaluation of the DEXTER® Robotic Surgery System for Total Hysterectomy with Adnexal Surgery.Journal of robotic surgery · 2025Observational
- Right Colectomy with Complete Mesocolic Excision and Intracorporeal Anastomosis: A Monocentric, Single-Surgeon Comparison of Dexter, DaVinci and Laparoscopic Approaches.Life (Basel, Switzerland) · 2025Article
- Robotic minimally invasive inguinal hernia repair with the Dexter robotic system™: A prospective multicenter clinical investigation.Surgical endoscopy · 2024Article
- The Combination of Laparoscopic and Robotic Surgery: First Experience with the Dexter Robotic System™ in Visceral Surgery.Life (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Robotic-assisted hysterectomy (RAH) is a widely accepted minimally invasive approach for uterus removal. However, as RAH is typically performed in the umbilical region, it usually results in scars in cosmetically suboptimal locations. This is the first case of RAH with cervicosacropexy performed below the bikini line, using the new Dexter robotic system™. Objectives: The aim of this article is to show the surgical steps of the first RAH with cervicosacropexy performed below the bikini line with the new Dexter robotic system™ (Distalmotion), and furthermore assess the feasibility of this approach using this robotic platform. Materials and Methods: A 43-year-old woman with uterine adenomyosis and recurrent uterine prolapse underwent a robotic-assisted subtotal hysterectomy with cervicosacropexy, performed below the bikini line, using the Dexter robotic system™, at the Clinic of Gynecology and Obstetrics at Universitätsklinikum Schleswig-Holstein (UKHS) in Kiel, Germany. Main outcome measures: Perioperative data, surgical approach specifics, objective, and subjective outcomes of this new approach. Results: The procedure was performed without intra-operative complications; estimated blood loss was 10 ml. Operative time was 150 minutes, console time 120 minutes, total docking time 6 minutes. Dexter performed as expected; no device-related issues or robotic arm collisions occurred. The patient did not require pain medication and was released on the second postoperative day. Conclusion: RAH performed below the bikini line using the Dexter robotic system™ is a feasible, safe, and adequate procedure. These initial results should be confirmed and further extensively refurbished with larger patient cohorts, and functional and psychological outcomes need further investigation.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.