Image Guided Intraoperative Radiation Therapy After Surgical Resection of Brain Metastases: A First In-Human Feasibility Report.
Article in Advances in radiation oncology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Intraoperative radiotherapy after resection of newly diagnosed brain metastases in adult patients - results of a prospective phase II trial (INTRAMET).Journal of neuro-oncology · 2026Trial
- Experimental evaluation of an intraoperative-imaging based workflow for electron beam radiotherapy of pancreatic cancer using in situ dosimetry.Journal of applied clinical medical physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: A correct placement of the applicator during intraoperative radiation therapy for brain metastasis is of paramount importance, to deliver a precise and safe treatment. The applicator-to-surface contact assessment cannot be performed under direct observation because the applicator itself limits the visual range. No image guided verification is currently performed intracranially. We hypothesize that image guided intraoperative radiation therapy would assure a more precise delivery in the target area. We describe our workflow in a first in-human experience. Methods and Materials: Phantom-based measurements were performed to reach the best cone beam computed tomography imaging quality possible. Once defined, a clinical feasibility study was initiated. An in-room cone beam computed tomography device is used to acquire intraoperative images after placing the applicator. Repositioning the applicator is thereafter discussed with the surgeon, according to the imaging outcomes, if required. Results: An optimal image quality was achieved with 120-kV voltage, 20-mA current, and a tube current time product of 150 mAs. An additional 0.51 mSv patient exposure was calculated for the entire procedure. The wide dynamic range (-600 HU to +600 HU) of cone beam computed tomography and a 27 HU mean computed tomography values difference between brain tissue and spherical applicator allows distinguishing both structures. In this first in-human experience, the applicator was repositioned after evidencing air gaps, assuring full applicator-to-surface contact. Conclusions: This first in-human procedure confirmed the feasibility of kilovoltage image guided intraoperative radiation therapy in a neurosurgical setting. A prospective study has been initiated and will provide further dosimetric details.