Volumetric computed tomography with carbon nanotube X-ray source array for improved image quality and accuracy.

Shuang Xu, Yuanming Hu, Boyuan Li, Christina R Inscoe, Donald A Tyndall, Yueh Z Lee, Jianping Lu, Otto Zhou

Abstract read
In one paragraph

Article in Communications engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Shuang XuDepartment of Applied Physical Sciences, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Yuanming HuDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.ORCID 0009-0000-7211-315X
Boyuan LiDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Christina R InscoeDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Donald A TyndallDepartment of Diagnostic Sciences, Adams School of Dentistry, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.
Yueh Z LeeDepartment of Radiology, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.ORCID 0000-0003-1846-7680
Jianping LuDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.ORCID 0000-0001-9963-9741
Otto ZhouDepartment of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599, USA.ORCID 0000-0003-1476-5517

Funding

Improve the diagnostic accuracy of CBCT for oral lesionsR56DE030962 · NIDCR · UNIV OF NORTH CAROLINA CHAPEL HILL · PI ZHOU, OTTO Z · 2021 to 2021
$512k
NIDCR NIH HHS R56 DE030962
6 · The paper itself

Abstract

Cone beam computed tomography (CBCT) is widely used in medical and dental imaging. Compared to a multidetector CT, it provides volumetric images with high isotropic resolution at a reduced radiation dose, cost and footprint without the need for patient translation. The current CBCT has several intrinsic limitations including reduced soft tissue contrast, inaccurate quantification of X-ray attenuation, image distortions and artefacts, which have limited its clinical applications primarily to imaging hard tissues and made quantitative analysis challenging. Here we report a multisource CBCT (ms-CBCT) which overcomes the short-comings of the conventional CBCT by using multiple narrowly collimated and rapidly scanning X-ray beams from a carbon nanotube field emission source array. Phantom imaging studies show that, the ms-CBCT increases the accuracy of the Hounsfield unit values by 60%, eliminates the cone beam artefacts, extends the axial coverage, and improves the soft tissue contrast-to-noise ratio by 30-50%, compared to the CBCT configuration.