Volumetric computed tomography with carbon nanotube X-ray source array for improved image quality and accuracy.
Article in Communications engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- A Dual-Energy CBCT With Reduced Scatter and Cone Beam Artifacts Using an X-Ray Source Array and Interlaced Spectral Filters.IEEE transactions on bio-medical engineering · 2026Article
- One-for-All Adaptive Radiotherapy Planning Agent: A Foundation Framework for Daily CBCT-guided Radiotherapy.ArXiv · 2026Article
- Feasibility of multisource CBCT for improving the predictability of dental implant primary stability compared to conventional CBCT.Scientific reports · 2026Article
- Low-cost dual-energy CBCT by spectral filtration of a dual focal spot X-ray source.Scientific reports · 2024Article
- A carbon nanotube x-ray source array designed for a new multisource cone beam computed tomography scanner.Physics in medicine and biology · 2024Article
- Improving the accuracy of bone mineral density using a multisource CBCT.Scientific reports · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Cone beam computed tomography (CBCT) is widely used in medical and dental imaging. Compared to a multidetector CT, it provides volumetric images with high isotropic resolution at a reduced radiation dose, cost and footprint without the need for patient translation. The current CBCT has several intrinsic limitations including reduced soft tissue contrast, inaccurate quantification of X-ray attenuation, image distortions and artefacts, which have limited its clinical applications primarily to imaging hard tissues and made quantitative analysis challenging. Here we report a multisource CBCT (ms-CBCT) which overcomes the short-comings of the conventional CBCT by using multiple narrowly collimated and rapidly scanning X-ray beams from a carbon nanotube field emission source array. Phantom imaging studies show that, the ms-CBCT increases the accuracy of the Hounsfield unit values by 60%, eliminates the cone beam artefacts, extends the axial coverage, and improves the soft tissue contrast-to-noise ratio by 30-50%, compared to the CBCT configuration.