Evidence map›Paper›PMID 38549245›Full record

ArticleClinical endoscopy2024

Safety and efficacy of novel oblique-viewing scope for B2-endoscopic ultrasound-guided hepaticogastrostomy.

Sho Ishikawa, Kazuo Hara, Nozomi Okuno, Nobumasa Mizuno, Shin Haba, Takamichi Kuwahara, Yasuhiro Kuraishi, Takafumi Yanaidani, Masanori Yamada, Tsukasa Yasuda and 3 more

Abstract read
In one paragraph

Article in Clinical endoscopy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Sho IshikawaDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Kazuo HaraDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Nozomi OkunoDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Nobumasa MizunoDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Shin HabaDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Takamichi KuwaharaDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Yasuhiro KuraishiDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Takafumi YanaidaniDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Masanori YamadaDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Tsukasa YasudaDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Toshitaka FukuiDepartment of Gastroenterology, Aichi Cancer Center Hospital, Nagoya, Japan.
Teru KumagiPost Graduate Medical Education Center, Ehime University Hospital, Toon, Japan.
Yoichi HiasaDepartment of Gastroenterology and Metabology, Ehime University Graduate School of Medicine, Toon, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND/

aimsEndoscopic ultrasound (EUS)-guided hepaticogastrostomy (EUS-HGS) performed at the intrahepatic bile duct segment 3 (B3) is widely used for biliary drainage. Although performing post-puncture procedures is easier in the intrahepatic bile duct segment 2 (B2) when using a conventional oblique-viewing (OV) EUS scope, this method may cause transesophageal puncture and severe adverse events. We evaluated the safety and efficacy of B2 puncture using a novel OV-EUS scope.

methodsIn this single-center retrospective study, we prospectively enrolled and collected data from 45 patients who consecutively underwent EUS-HGS procedures with a novel OV-EUS scope between September 2021 and December 2022 at our cancer center.

resultsThe technical success rates of B2-EUS-HGS and EUS-HGS were 93.3% (42/45) and 97.8% (44/45), respectively. The early adverse event rate was 8.9% (4/45) with no cases of scope changes or transesophageal punctures. The median procedure time was 13 minutes (range, 5-30).

conclusionsB2-EUS-HGS can be performed safely with the novel EG-740UT (Fujifilm) OV-scope without transesophageal puncture and with a high success rate. B2-EUS-HGS using this novel OV scope may be the preferred strategy for EUS-HGS.

Indexed as

Bile ductsEndoscopyGastrostomyPuncturesUltrasonography

Identifiers

PMID38549245
PMCPMC11294849

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.