Evidence map›Paper›PMID 38545209›Full record

ArticleHeliyon2024

Design method of a focusing dielectric lens antenna and temperature increment measurement at the focusing spot.

Amirah Abd Rahman, Kamilia Kamardin, Yoshihide Yamada, Masaharu Takahashi

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Amirah Abd RahmanDepartment of Electronic Systems Engineering, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Kuala Lumpur, Malaysia.
Kamilia KamardinDepartment of Electronic Systems Engineering, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Kuala Lumpur, Malaysia.
Yoshihide YamadaDepartment of Electronic Systems Engineering, Malaysia-Japan International Institute of Technology, Universiti Teknologi Malaysia, Kuala Lumpur, Malaysia.
Masaharu TakahashiCenter for Frontier Medical Engineering, Chiba University, Japan.
University of Technology Malaysia · MYChiba University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In radio wave hyperthermia therapy, array antenna configuration was mainly studied to generate a small spot at the diseased part. Array antennas have the flexibility in controlling radiation performance, such as spot positions, by using their numerous radiating elements. However, the flexibility is achieved at the expense of antenna structure complexity. On the other hand, a lens antenna can concentrate radio waves into a small spot by forming a lens shape. The simplicity of a lens antenna structure lends itself to easy handling in a practical application. Moreover, the frequency independence of the lens antenna allows for a more flexible selection of hyperthermia therapy frequencies. Therefore, the lens antenna is selected as a focusing antenna in this paper. The lens shaping method and the temperature increment measurement are the main contents of this paper. The designed lens has a diameter of 30 cm, a focusing distance of 30 cm, and a working frequency of 2.45 GHz. A thin lens design method is applied to reduce lens weight. Firstly, the focusing ability of the designed lens is ensured by comparing the spot size results of electromagnetic (EM) simulation with its theoretical value. A spot size of 1.77 cm is obtained in both cases. Next, the temperature increment is examined by EM simulations. The temperature at the 2 cm tumor was increased to 41 °C from the human body temperature of 37 °C by an input power of 10 Watts (W). For the temperature increment measurement, a tumor within human body phantom is utilized and the available input power is reduced to 4 W. The tumor temperature increased from 21.5 °C of room temperature to 24.4 °C, which was captured by a thermal imaging camera. As a result, the functionality of the lens antenna for hyperthermia therapy is verified.

Indexed as

Dielectric lens antennaHuman body phantomRadio wave hyperthermiaSmall focal spot

Identifiers

PMID38545209
PMCPMC10965516
OpenAlexW4392858035

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.