ArticleQuantitative imaging in medicine and surgery2024
Deep learning-based partial volume correction in standard and low-dose positron emission tomography-computed tomography imaging.
Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Deep learning-based restoration of PET images from a dual-panel breast dedicated scanner.Zeitschrift fur medizinische Physik · 2026Article
- Optimizing acquisition time and injected dose inBMC medical informatics and decision making · 2026Article
- Evaluating the impact of partial volume correction on FDG PET radiomics stability in lymphoma lesions.Physical and engineering sciences in medicine · 2026Article
- Simultaneous partial volume correction and denoising of brain PET images, using transformers and transfer learning.EJNMMI research · 2026Article
- Impact of partial volume correction on radiomics reproducibility in theranostic SPECT/CT imaging.Medical physics · 2026Article
- Critical review of partial volume correction methods in PET and SPECT imaging: benefits, pitfalls, challenges, and future outlook.European journal of nuclear medicine and molecular imaging · 2026Review
- Supervised Volumetric Segmentation of White and Gray Matter from Brain Positron Emission Tomography Images Using Magnetic Resonance Labels.Journal of medical signals and sensors · 2026Article
- Review
- Review
- Targeted radioligand therapy: physics and biology, internal dosimetry and other practical aspects duringTheranostics · 2025Review
- Enhancing Amyloid PET Quantification: MRI-Guided Super-Resolution Using Latent Diffusion Models.Life (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Positron emission tomography (PET) imaging encounters the obstacle of partial volume effects, arising from its limited intrinsic resolution, giving rise to (I) considerable bias, particularly for structures comparable in size to the point spread function (PSF) of the system; and (II) blurred image edges and blending of textures along the borders. We set out to build a deep learning-based framework for predicting partial volume corrected full-dose (FD + PVC) images from either standard or low-dose (LD) PET images without requiring any anatomical data in order to provide a joint solution for partial volume correction and de-noise LD PET images. Methods: We trained a modified encoder-decoder U-Net network with standard of care or LD PET images as the input and FD + PVC images by six different PVC methods as the target. These six PVC approaches include geometric transfer matrix (GTM), multi-target correction (MTC), region-based voxel-wise correction (RBV), iterative Yang (IY), reblurred Van-Cittert (RVC), and Richardson-Lucy (RL). The proposed models were evaluated using standard criteria, such as peak signal-to-noise ratio (PSNR), root mean squared error (RMSE), structural similarity index (SSIM), relative bias, and absolute relative bias. Results: Different levels of error were observed for these partial volume correction methods, which were relatively smaller for GTM with a SSIM of 0.63 for LD and 0.29 for FD, IY with an SSIM of 0.63 for LD and 0.67 for FD, RBV with an SSIM of 0.57 for LD and 0.65 for FD, and RVC with an SSIM of 0.89 for LD and 0.94 for FD PVC approaches. However, large quantitative errors were observed for multi-target MTC with an RMSE of 2.71 for LD and 2.45 for FD and RL with an RMSE of 5 for LD and 3.27 for FD PVC approaches. Conclusions: We found that the proposed framework could effectively perform joint de-noising and partial volume correction for PET images with LD and FD input PET data (LD
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.