Evidence map›Paper›PMID 38545040›Full record

ArticleQuantitative imaging in medicine and surgery2024

Automatic detection of cerebral microbleeds using susceptibility weighted imaging and artificial intelligence.

Yu Luo, Ke Gao, Miller Fawaz, Bo Wu, Yi Zhong, Yong Zhou, Ewart Mark Haacke, Yongming Dai, Shiyuan Liu

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 2 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 2 syntheses or guidelines pooled it, 6 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Review
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Yu Luo *Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai, China.
Ke Gao *Department of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai, China.ORCID https://orcid.org/0000-0001-8341-0125
Miller FawazSpinTech MRI, Bingham Farms, MI, USA.
Bo WuShanghai Zhuyan, Inc., Shanghai, China.
Yi ZhongSpinTech MRI, Bingham Farms, MI, USA.
Yong ZhouDepartment of Radiology, Shanghai Fourth People's Hospital, School of Medicine, Tongji University, Shanghai, China.
Ewart Mark HaackeDepartments of Biomedical Engineering, Neurology and Radiology, Wayne State University, Detroit, MI, USA.
Yongming DaiSchool of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, Shanghai, China.
Shiyuan LiuSchool of Medicine, Tongji University, Shanghai, China.
Tongji University · CNMagnetic Resonance Innovations (United States) · USShanghaiTech University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Efficiently and accurately detecting cerebral microbleeds (CMBs) is crucial for diagnosing dementia, stroke, and traumatic brain injury. Manual CMB detection, however, is time-consuming and error-prone. This study evaluates a novel artificial intelligence (AI) software designed for the automated detection of CMBs using susceptibility weighted imaging (SWI). Methods: The SWI data from 265 patients, 206 of whom had a history of stroke and others of whom presented a variety of other medical histories, including hypertension, diabetes, hyperlipidemia, cerebral hemorrhage, intracerebral vascular malformations, tumors, and inflammation, collected between January 2015 and December 2018, were analyzed. Two independent radiologists initially reviewed the images to identify and count the number of CMBs. Subsequently, the images were processed using an automatic CMB detection software. The generated reports were then reviewed by the radiologists. A final consensus between the two radiologists, obtained after a second review of the images, was used to compare results obtained from the initial manual detection and those of the automatic CMB detection software. The differences of detection sensitivity and precision for patients with or without CMBs and for individual CMBs between the radiologist and the automatic CMB detection software were compared using Pearson chi-squared tests. Results: A total of 1,738 CMBs were detected among 148 patients (71.4±10.7 years, 100 males) from the analyzed SWI data. While the radiologists identified 139 cases with CMBs, the automatic CMB detection software detected 145 cases. Nevertheless, there was no statistical difference in the sensitivity and specificity of the automatic CMB detection software compared to manual detection in determining patients with CMBs (P=0.656 and P=0.212, chi-square test). However, the radiologist identified 93 patients without CMBs, while the automatic CMB detection software detected 121 patients without CMBs, exhibiting a statistically significant difference (P=0.016, chi-square test). In terms of individual CMBs, the radiologists found 1,284, whereas the automatic CMB detection software detected 1,677 CMBs. The detection sensitivity for human versus the automatic CMB detection software were 75.5% and 96.5% respectively (P<0.001, chi-square test), while the precision rates were 92.2% and 86.0% (P<0.001, chi-square test), respectively. Notably, the radiologists were more likely to overlook CMBs when the number of CMBs was high (above 30). Conclusions: The automatic CMB detection software proved to be an effective tool for the detection and quantification of CMBs. It demonstrated higher sensitivity than the radiologists, especially in detecting minuscule CMBs and in cases with high CMB prevalence.

Indexed as

artificial intelligence (AI)Microbleedsprecisionsensitivitysusceptibility weighted imaging (SWI)

Identifiers

PMID38545040
PMCPMC10963806
OpenAlexW4392593781

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.