Evidence map›Paper›PMID 38544153›Full record

ArticleSensors (Basel, Switzerland)2024

The Feasibility of Semi-Continuous and Multi-Frequency Thoracic Bioimpedance Measurements by a Wearable Device during Fluid Changes in Hemodialysis Patients.

Melanie K Schoutteten, Lucas Lindeboom, Hélène De Cannière, Zoë Pieters, Liesbeth Bruckers, Astrid D H Brys, Patrick van der Heijden, Bart De Moor, Jacques Peeters, Chris Van Hoof and 3 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Trial
  2. Observational
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Melanie K SchouttetenLimburg Clinical Research Center/Mobile Health Unit, Faculty of Biomedical and Life Sciences, Hasselt University, Agoralaan, 3590 Diepenbeek, Belgium.ORCID 0000-0002-7217-2405
Lucas LindeboomDepartment of Health Research, imec the Netherlands/Holst Centre, High Tech Campus 31, 5656 AE Eindhoven, The Netherlands.
Hélène De CannièreLimburg Clinical Research Center/Mobile Health Unit, Faculty of Biomedical and Life Sciences, Hasselt University, Agoralaan, 3590 Diepenbeek, Belgium.ORCID 0000-0002-7681-3011
Zoë PietersData Science Institute, Hasselt University, 3500 Hasselt, Belgium.ORCID 0000-0002-7288-4461
Liesbeth BruckersData Science Institute, Hasselt University, 3500 Hasselt, Belgium.ORCID 0000-0002-6978-3002
Astrid D H BrysDivision of Geriatrics, Department of Internal Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, The Netherlands.
Patrick van der HeijdenDepartment of Health Research, imec the Netherlands/Holst Centre, High Tech Campus 31, 5656 AE Eindhoven, The Netherlands.ORCID 0000-0001-5020-8086
Bart De MoorLimburg Clinical Research Center/Mobile Health Unit, Faculty of Biomedical and Life Sciences, Hasselt University, Agoralaan, 3590 Diepenbeek, Belgium.
Jacques PeetersDepartment of Nephrology, Ziekenhuis Oost Limburg, Synaps Park 1, 3600 Genk, Belgium.
Chris Van HoofImec Belgium, Kapeldreef 75, 3001 Leuven, Belgium.
Willemijn GroenendaalDepartment of Health Research, imec the Netherlands/Holst Centre, High Tech Campus 31, 5656 AE Eindhoven, The Netherlands.
Jeroen P KoomanDivision of Nephrology, Department of Internal Medicine, Maastricht University Medical Centre+, P. Debyelaan 25, 6202 AZ Maastricht, The Netherlands.
Pieter M VandervoortLimburg Clinical Research Center/Mobile Health Unit, Faculty of Biomedical and Life Sciences, Hasselt University, Agoralaan, 3590 Diepenbeek, Belgium.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Repeated single-point measurements of thoracic bioimpedance at a single (low) frequency are strongly related to fluid changes during hemodialysis. Extension to semi-continuous measurements may provide longitudinal details in the time pattern of the bioimpedance signal, and multi-frequency measurements may add in-depth information on the distribution between intra- and extracellular fluid. This study aimed to investigate the feasibility of semi-continuous multi-frequency thoracic bioimpedance measurements by a wearable device in hemodialysis patients. Therefore, thoracic bioimpedance was recorded semi-continuously (i.e., every ten minutes) at nine frequencies (8-160 kHz) in 68 patients during two consecutive hemodialysis sessions, complemented by a single-point measurement at home in-between both sessions. On average, the resistance signals increased during both hemodialysis sessions and decreased during the interdialytic interval. The increase during dialysis was larger at 8 kHz (∆ 32.6 Ω during session 1 and ∆ 10 Ω during session 2), compared to 160 kHz (∆ 29.5 Ω during session 1 and ∆ 5.1 Ω during session 2). Whereas the resistance at 8 kHz showed a linear time pattern, the evolution of the resistance at 160 kHz was significantly different (

Indexed as

Renal DialysisWearable Electronic DevicesElectric ImpedanceExtracellular FluidFeasibility StudiesHumansbioimpedancemulti-frequencysemi continuousthoracicwearable

Identifiers

PMID38544153
PMCPMC10976053

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.