Evidence map›Paper›PMID 38544110›Full record

ArticleSensors (Basel, Switzerland)2024

Development of a Small-Footprint 50 MHz Linear Array: Fabrication and Micro-Ultrasound Imaging Demonstration.

Carlos-Felipe Roa, Emmanuel Chérin, Nidhi Singh, Jianhua Yin, Aaron Boyes, F Stuart Foster, Christine E M Demore

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Carlos-Felipe RoaDepartment of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.ORCID 0000-0001-5781-9592
Emmanuel ChérinSunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.ORCID 0000-0002-6787-025X
Nidhi SinghDepartment of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.
Jianhua YinSunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
Aaron BoyesSunnybrook Research Institute, Toronto, ON M4N 3M5, Canada.
F Stuart FosterDepartment of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.
Christine E M DemoreDepartment of Medical Biophysics, University of Toronto, Toronto, ON M5G 1L7, Canada.ORCID 0000-0003-4931-6463

Funding

Natural Sciences and Engineering Research Council RGPIN-2017-06834Terry Fox Research Institute 0
6 · The paper itself

Abstract

Compact high-frequency arrays are of interest for clinical and preclinical applications in which a small-footprint or endoscopic device is needed to reach the target anatomy. However, the fabrication of compact arrays entails the connection of several dozens of small elements to the imaging system through a combination of flexible printed circuit boards at the array end and micro-coaxial cabling to the imaging system. The methods currently used, such as wire bonding, conductive adhesives, or a dry connection to a flexible circuit, considerably increase the array footprint. Here, we propose an interconnection method that uses vacuum-deposited metals, laser patterning, and electroplating to achieve a right-angle, compact, reliable connection between array elements and flexible-circuit traces. The array elements are thickened at the edges using patterned copper traces, which increases their cross-sectional area and facilitates the connection. We fabricated a 2.3 mm by 1.7 mm, 64-element linear array with elements at a 36 μm pitch connected to a 4 cm long flexible circuit, where the interconnect adds only 100 μm to each side of the array. Pulse-echo measurements yielded an average center frequency of 55 MHz and a -6 dB bandwidth of 41%. We measured an imaging resolution of 35 μm in the axial direction and 114 μm in the lateral direction and demonstrated the ex vivo imaging of porcine esophageal tissue and the in vivo imaging of avian embryonic vasculature.

Indexed as

TransducersAnimalsElectric ImpedanceEquipment DesignPhantoms, ImagingSwineUltrasonographyacoustic characterizationelectrical characterizationelectrode patterningexcimer laserfine pitchflexible-circuit cablinghigh-density interconnecthigh-frequency ultrasoundlaser machiningmetal depositionminiaturizationpolyimidetransducer array

Identifiers

PMID38544110
PMCPMC10974379

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.