Evidence map›Paper›PMID 38544018›Full record

ArticleSensors (Basel, Switzerland)2024

Embedded Wireless Sensor for In Situ Concrete Internal Relative Humidity Monitoring.

Tai Ikumi, Ignasi Cairó, Jan Groeneveld, Antonio Aguado, Albert de la Fuente

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Tai IkumiSmart Engineering Ltd., 08006 Barcelona, Spain.
Ignasi CairóWitekLab, 08223 Terrassa, Spain.
Jan GroeneveldWitekLab, 08223 Terrassa, Spain.
Antonio AguadoSmart Engineering Ltd., 08006 Barcelona, Spain.ORCID 0000-0001-5542-6365
Albert de la FuenteDepartment of Civil and Environmental Engineering, Universitat Politècnica de Catalunya, 08034 Barcelona, Spain.ORCID 0000-0002-8016-1677

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The moisture content within the concrete pore network significantly influences the mechanical, thermal, and durability characteristics of concrete structures. This paper introduces a novel fully embedded wireless temperature and relative humidity sensor connected to an automatic acquisition system designed for continuous concrete monitoring. Relative humidity measurements from this new sensor are compared with those obtained by a commercial system based on the borehole method at different depths (2.5 and 4.0 cm) and exposure conditions (oven drying and humid chamber). The results allow for proving that both systems provide consistent internal relative humidity measurements aligned with the exposure conditions and highlight the capability of fully embedded wireless sensors as a practical and reliable alternative to the conventional borehole method. Additionally, the continuous monitoring of the wireless cast-in sensor exhibits reliability during unintended temperature fluctuations, emphasizing the effectiveness of permanently installed sensors in promptly detecting unintended curing variations in real time. The continuous real-time information provided combined with the practicality of these sensors might assist construction managers to improve the quality control of the concrete curing process and shrinkage behavior, and ensure the integrity of concrete surface finishing.

Indexed as

concretemonitoringrelative humiditytemperaturewireless sensor networks

Identifiers

PMID38544018
PMCPMC10975170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.