Evidence map›Paper›PMID 38542613›Full record

ArticleMicromachines2024

Single-Ended Eddy Current Micro-Displacement Sensor with High Precision Based on Temperature Compensation.

Zhengping Xu, Yongtong Feng, Yi Liu, Fengxin Shi, Yang Ge, Han Liu, Wei Cao, Hong Zhou, Shuang Geng, Wenqi Lin

Abstract read
In one paragraph

Article in Micromachines, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Zhengping XuSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Yongtong FengSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Yi LiuSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.ORCID 0000-0002-8011-4088
Fengxin ShiSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Yang GeSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Han LiuSuzhou Guoke Medical Technology Development (Group) Co., Ltd., Suzhou 215163, China.
Wei CaoSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Hong ZhouSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.
Shuang GengSuzhou Guoke Medical Technology Development (Group) Co., Ltd., Suzhou 215163, China.
Wenqi LinSuzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To measure the micro-displacement reliably with high precision, a single-ended eddy current sensor based on temperature compensation was studied in detail. At first, the principle of the eddy current sensor was introduced, and the manufacturing method of the probe was given. The overall design plan for the processing circuit was induced by analyzing the characteristics of the probe output signal. The variation in the probe output signal was converted to pulses with different widths, and then it was introduced to the digital phase discriminator along with a reference signal. The output from the digital phase discriminator was processed by a low-pass filter to obtain the DC component. At last, the signal was amplified and compensated to reduce the influence of temperature. The selection criteria of the frequency of the exciting signal and the design of the signal conditioning circuit were described in detail, as well as the design of the temperature-compensating circuit based on the digital potentiometer with an embedded temperature sensor. Finally, an experimental setup was constructed to test the sensor, and the results were given. The results show that nonlinearity exists in the single-ended eddy current sensor with a large range. When the range is 500 μm, the resolution can reach 46 nm, and the repeatability error is ±0.70% FR. Within the temperature range from +2 °C to +58 °C, the voltage fluctuation in the sensor is reduced to 44 mV after temperature compensation compared to the value of 586 mV before compensation. The proposed plan is verified to be feasible, and the measuring range, precision, and target material should be considered in real-world applications.

Indexed as

digital phase discriminatoreddy current sensormicro-displacementtemperature compensation

Identifiers

PMID38542613
PMCPMC10972287

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.