ArticleJournal of personalized medicine2024

Characterization of Plastic Scintillator Detector for In Vivo Dosimetry in Gynecologic Brachytherapy.

Antonio Herreros, José Pérez-Calatayud, Facundo Ballester, Rosa Abellana, Joana Neves, Joana Melo, Luis Moutinho, Jordi Tarrats-Rosell, Sergi Serrano-Rueda, Luca Tagliaferri and 2 more

Abstract read
In one paragraph

Article in Journal of personalized medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Antonio HerrerosFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.ORCID 0000-0001-9867-481X
José Pérez-CalatayudRadiation Oncology Department, Hospital Universitari i Politècnic La Fe, 46026 Valencia, Spain.
Facundo BallesterIRIMED, IIS-La Fe-Universitat de Valencia (UV), 46100 Burjassot, Spain.
Rosa AbellanaFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.
Joana NevesNU-RISE S.A., PCI-Creative Science Park, 3830-352 Ilhavo, Portugal.
Joana MeloNU-RISE S.A., PCI-Creative Science Park, 3830-352 Ilhavo, Portugal.
Luis MoutinhoNU-RISE S.A., PCI-Creative Science Park, 3830-352 Ilhavo, Portugal.
Jordi Tarrats-RosellRadiation Oncology Department, Hospital Clínic Universitari, 08036 Barcelona, Spain.ORCID 0000-0003-4380-8045
Sergi Serrano-RuedaRadiation Oncology Department, Hospital Clínic Universitari, 08036 Barcelona, Spain.ORCID 0000-0002-3288-3536
Luca TagliaferriDipartimento di Diagnostica per Immagini e Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy.ORCID 0000-0003-2308-0982
Elisa PlacidiDipartimento di Diagnostica per Immagini e Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy.ORCID 0000-0003-4613-6870
Angeles RovirosaFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.ORCID 0000-0002-7832-334X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: High dose gradients and manual steps in brachytherapy treatment procedures can lead to dose errors which make the use of in vivo dosimetry (IVD) highly recommended for verifying brachytherapy treatments. A new procedure was presented to obtain a calibration factor which allows fast and robust calibration of plastic scintillation detector (PSD) probes for the geometry of a compact phantom using Monte Carlo simulations. Additionally, characterization of PSD energy, angular, and temperature dependences was performed. (2) Methods: PENELOPE/PenEasy code was used to obtain the calibration factor. To characterize the energy dependence of the PSD, the signal was measured at different radial and transversal distances. The sensitivity to the angular position was characterized in axial and azimuthal planes. (3) Results: The calibration factor obtained allows for an absorbed dose to water determination in full scatter conditions from ionization measured in a mini polymethylmethacrylate (PMMA) phantom. The energy dependence of the PSD along the radial distances obtained was (2.3 ± 2.1)% (