An automated technique for global noise level measurement in CT image with a conjunction of image gradient.

Hsiang-Chi Kuo, Usman Mahmood, Assen S Kirov, James Mechalakos, Cesar Della Biancia, Laura I Cerviño, Seng Boh Lim

Abstract read
In one paragraph

Article in Physics in medicine and biology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Patient-specific Channelized Hotelling observer to estimate lesion detectability in CT.Proceedings of SPIE--the International Society for Optical Engineering · 2025
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hsiang-Chi KuoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.
Usman MahmoodDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.
Assen S KirovDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.
James MechalakosDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.ORCID 0000-0001-9373-836X
Cesar Della BianciaDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.
Laura I CerviñoDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.
Seng Boh LimDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, NY, United States of America.

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

Automated assessment of noise level in clinical computed tomography (CT) images is a crucial technique for evaluating and ensuring the quality of these images. There are various factors that can impact CT image noise, such as statistical noise, electronic noise, structure noise, texture noise, artifact noise, etc. In this study, a method was developed to measure the global noise index (GNI) in clinical CT scans due to the fluctuation of x-ray quanta. Initially, a noise map is generated by sliding a 10 × 10 pixel for calculating Hounsfield unit (HU) standard deviation and the noise map is further combined with the gradient magnitude map. By employing Boolean operation, pixels with high gradients are excluded from the noise histogram generated with the noise map. By comparing the shape of the noise histogram from this method with Christianson's tissue-type global noise measurement algorithm, it was observed that the noise histogram computed in anthropomorphic phantoms had a similar shape with a close GNI value. In patient CT images, excluding the HU deviation due the structure change demonstrated to have consistent GNI values across the entire CT scan range with high heterogeneous tissue compared to the GNI values using Christianson's tissue-type method. The proposed GNI was evaluated in phantom scans and was found to be capable of comparing scan protocols between different scanners. The variation of GNI when using different reconstruction kernels in clinical CT images demonstrated a similar relationship between noise level and kernel sharpness as observed in uniform phantom: sharper kernel resulted in noisier images. This indicated that GNI was a suitable index for estimating the noise level in clinical CT images with either a smooth or grainy appearance. The study's results suggested that the algorithm can be effectively utilized to screen the noise level for a better CT image quality control.

Indexed as

AlgorithmsTomography, X-Ray ComputedArtifactsHumansImage Processing, Computer-AssistedPhantoms, ImagingQuality ControlRadiation DosageCTglobal noise indeximage qualitynoise

Identifiers

PMID38537310
PMCPMC11608062

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.