Evidence map›Paper›PMID 38537013›Full record

ArticleBrazilian dental journal2024

Assessing peri-implant bone microarchitecture: conventional vs. osseodensification drilling - ex vivo analysis.

Breno Fortes Bittar, Bruno Salles Sotto-Maior, Karina Lopes Devito, Gustavo Davi Rabelo, Alessandra Silveira Machado, Ricardo Tadeu Lopes, Neuza Maria Souza Picorelli Assis

Abstract read
In one paragraph

Article in Brazilian dental journal, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Breno Fortes BittarSchool of Dentistry, Universidade Federal de Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.ORCID http://orcid.org/0000-0002-7037-3705
Bruno Salles Sotto-MaiorSchool of Dentistry, Universidade Federal de Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.ORCID http://orcid.org/0000-0002-9462-0299
Karina Lopes DevitoSchool of Dentistry, Universidade Federal de Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.ORCID http://orcid.org/0000-0001-5037-5466
Gustavo Davi RabeloSchool of Dentistry, Universidade Federal de Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.ORCID http://orcid.org/0000-0001-9511-5078
Alessandra Silveira MachadoNuclear Instrumentation Laboratory - COPPE/UFRJ, Federal University of Rio de Janeiro. Rio de Janeiro, Brazil.ORCID http://orcid.org/0000-0002-7973-9611
Ricardo Tadeu LopesNuclear Instrumentation Laboratory - COPPE/UFRJ, Federal University of Rio de Janeiro. Rio de Janeiro, Brazil.ORCID http://orcid.org/0000-0001-7250-824X
Neuza Maria Souza Picorelli AssisSchool of Dentistry, Universidade Federal de Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.ORCID http://orcid.org/0000-0002-8612-5044

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim was to evaluate primary implant stability and bone microarchitecture in two drilling situations, by comparing the conventional technique (CT) and osseodensification (OD) (Versah Burs - Jackson - Mississippi - USA). The implant insertion torque (IT), implant stability quotient (ISQ), and the peri-implant trabecular microstructure were assessed on bone fragments obtained from pig's tibia (n=12), divided between CT (n=6) and OD (n=6). After the drilling procedure, the implants were installed (3.5x8.5 mm, Epikut - SIN - São Paulo - Brazil). The IT and ISQ were measured using a digital torque wrench and resonance frequency analysis. Then, the bone fragments containing the implants were removed with a trephine and analyzed by Microtomography (µCT, 8.0 µm). The comparison between groups was performed using the unpaired t-test (α=0.05). The results revealed that OD promotes a higher insertion torque (CT: 7.67±2.44 Ncm; OD: 19.78±5.26 Ncm) (p=0.0005), although ISQ was not different (CT: 61.33±4.66; OD: 63.25±4.58) (p=0.48). There was a significant increase in peri-implant bone volume (CT: 23.17±3.39 mm3; OD: 32.01±5.75 mm3) (p=0.008), and trabecular parameters: separation (CT: 0.4357±0.03 mm; OD: 0.3865±0.04 mm) (p=0.0449), number (CT: 1.626±0.18 1/mm; OD: 1.946±0.13 1/mm) (p=0.007), and thickness (CT: 0.1130±0.009 mm; OD: 0.1328±0.015 mm) (p=0.02). Structure model index (SMI) data demonstrate no significant differences between groups (CT: 1.7±0.2; OD: 1.4±0.4) (p=0.12). In conclusion, OD increases the insertion torque values and promotes beneficial changes regarding bone microarchitecture compared with CT, revealing more peri-implant bone volume with consequent higher primary stability.

Indexed as

Dental ImplantsBrazilDental Implantation, EndosseousTorqueDental Implants

Identifiers

PMID38537013
PMCPMC10976315

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.