ArticleNanomaterials (Basel, Switzerland)2024
A Light-Powered Micropump with Dynamic Collective Behavior for Reparation.
Article in Nanomaterials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Light-guided SERS-active micromotor clusters for on-site detection of microorganisms.Analytical and bioanalytical chemistry · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
Abstract
Inspired by the collective behaviors of active systems in nature, the collective behavior of micromotors has attracted more and more attention in recent years. However, little attention has been paid to the collective behavior of the immobilized micromotor, i.e., the micropump. In this paper, a unique pentacene-based micropump is reported, which demonstrates dynamic collective behavior activated by white light irradiation. The light irradiation may generate the photochemical reactions between pentacene and water, leading to the electroosmotic flow. As a result, this micropump is capable of pumping the surrounding solution inward along the substrate surface based on the electroosmosis mechanism. Intriguingly, the inward pumping causes the agglomeration of the tracer particles on the surface of the micropump. In addition, the aggregation can migrate following the change in the light irradiation position between two adjacent micropumps. Based on the aggregating and migrating behaviors of this pentacene-based micropump, we have achieved the conductivity restoration of the cracked circuit.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.