ArticleNanomaterials (Basel, Switzerland)2024
Design and Analysis of the Dual-Band Far-Field Super-Resolution Metalens with Large Aperture.
Article in Nanomaterials (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Review for optical metalens based on metasurfaces: fabrication and applications.Microsystems & nanoengineering · 2025Review
- Compact Near-Infrared Imaging Device Based on a Large-Aperture All-Si Metalens.Nanomaterials (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
Abstract
The resolving power of metalens telescopes rely on their aperture size. Flat telescopes are advancing with the research on super-resolution confocal metalenses with large aperture. However, the aperture sizes of metalenses are usually bound within hundreds of micrometers due to computational and fabrication challenges, limiting their usage on practical optical devices like telescopes. In this work, we demonstrated a two-step designing method for the design of dual-band far-field super-resolution metalens with aperture sizes from the micro-scale to macro-scale. By utilizing two types of inserted unit cells, the phase profile of a dual-wavelength metalens with a small aperture of 100 μm was constructed. Through numerical simulation, the measured FWHM values of the focal spots of 5.81 μm and 6.81 μm at working wavelengths of 632.8 nm and 1265.6 nm were found to all be slightly smaller than the values of 0.61 λ/NA, demonstrating the super-resolution imaging of the designed metalens. By measuring the optical power ratio of the focal plane and the incident plane, the focusing efficiencies were 76% at 632.8 nm and 64% at 1265.6 nm. Based on the design method for small-aperture metalens, far-field imaging properties through the macro metalens with an aperture of 40 mm were simulated by using the Huygens-Fresnel principle. The simulation results demonstrate confocal far-field imaging behavior at the target wavelengths of 632.8 nm and 1265.6 nm, with a focal length of 200 mm. The design method for dual-band far-field super-resolution metalens with a large aperture opens a door towards the practical applications in the dual-band space telescope system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.