Evidence map›Paper›PMID 38534550›Full record

ArticleBioengineering (Basel, Switzerland)2024

Active Claw-Shaped Dry Electrodes for EEG Measurement in Hair Areas.

Zaihao Wang, Yuhao Ding, Wei Yuan, Hongyu Chen, Wei Chen, Chen Chen

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
3.4field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Zaihao WangCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China.
Yuhao DingCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China.
Wei YuanCenter for Intelligent Medical Equipment and Devices, Institute for Innovative Medical Devices, School of Biomedical Engineering, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei 230026, China.
Hongyu ChenCenter for Intelligent Medical Electronics, School of Information Science and Technology, Fudan University, Shanghai 200433, China.ORCID 0000-0003-4317-7554
Wei ChenSchool of Biomedical Engineering, The University of Sydney, Sydney, NSW 2006, Australia.
Chen ChenHuman Phenome Institute, Fudan University, Shanghai 201203, China.
Fudan University · CNThe University of Sydney · AUUniversity of Science and Technology of China · CN

Funding

Greater Bay Area Institute of Precision Medicine (Guangzhou) IPM2021C002
6 · The paper itself

Abstract

EEG, which can provide brain alteration information via recording the electrical activity of neurons in the cerebral cortex, has been widely used in neurophysiology. However, conventional wet electrodes in EEG monitoring typically suffer from inherent limitations, including the requirement of skin pretreatment, the risk of superficial skin infections, and signal performance deterioration that may occur over time due to the air drying of the conductive gel. Although the emergence of dry electrodes has overcome these shortcomings, their electrode-skin contact impedance is significantly high and unstable, especially in hair-covered areas. To address the above problems, an active claw-shaped dry electrode is designed, moving from electrode morphological design, slurry preparation, and coating to active electrode circuit design. The active claw-shaped dry electrode, which consists of a claw-shaped electrode and active electrode circuit, is dedicated to offering a flexible solution for elevating electrode fittings on the scalp in hair-covered areas, reducing electrode-skin contact impedance and thus improving the quality of the acquired EEG signal. The performance of the proposed electrodes was verified by impedance, active electrode circuit, eyes open-closed, steady-state visually evoked potential (SSVEP), and anti-interference tests, based on EEG signal acquisition. Experimental results show that the proposed claw-shaped electrodes (without active circuit) can offer a better fit between the scalp and electrodes, with a low electrode-skin contact impedance (18.62 KΩ@1 Hz in the hairless region and 122.15 KΩ@1 Hz in the hair-covered region). In addition, with the active circuit, the signal-to-noise ratio (SNR) of the acquiring EEG signal was improved and power frequency interference was restrained, therefore, the proposed electrodes can yield an EEG signal quality comparable to wet electrodes.

Indexed as

active electrodeclaw-shaped dry electrodeEEG signal collectionimpedance performance

Identifiers

PMID38534550
PMCPMC10968078
OpenAlexW4392763575

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.