Evidence map›Paper›PMID 38534529›Full record

ArticleBioengineering (Basel, Switzerland)2024

Femtosecond Laser Cutting of Human Crystalline Lens Capsule and Decellularization for Corneal Endothelial Bioengineering.

Olfa Ben Moussa, Louise Parveau, Inès Aouimeur, Grégory Egaud, Corantin Maurin, Sofiane Fraine, Sébastien Urbaniak, Chantal Perrache, Zhiguo He, Sedao Xxx and 5 more

Open access · goldAbstract read
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
3.2field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 3 institutions in 1 country.

Olfa Ben MoussaLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Louise ParveauLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.ORCID 0009-0003-2601-6350
Inès AouimeurLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Grégory EgaudGIE Manutech-USD, 18 Rue Professeur Benoît Lauras, 42000 Saint-Etienne, France.
Corantin MaurinLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.ORCID 0000-0002-0080-3423
Sofiane FraineLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Sébastien UrbaniakLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Chantal PerracheLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Zhiguo HeLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Sedao XxxLaboratoire Hubert Curien, Jean Monnet University, 18 Rue Professeur Benoît Lauras, 42000 Saint-Etienne, France.ORCID 0000-0003-4072-492X
Oliver Dorado CortezLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Sylvain PoinardLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.ORCID 0000-0003-3660-6541
Cyril MauclairLaboratoire Hubert Curien, Jean Monnet University, 18 Rue Professeur Benoît Lauras, 42000 Saint-Etienne, France.ORCID 0000-0001-5723-2281
Philippe GainLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.
Gilles ThuretLaboratory Biology, Engineering and Imaging for Ophthalmology, BiiO, Faculty of Medicine, Health Innovation Campus, Jean Monnet University, 10 Rue de la Marandière, 42270 Saint-Priest-en-Jarez, France.ORCID 0000-0003-3486-2875
Université Jean Monnet · FRCentre Hospitalier Universitaire de Saint-Étienne · FRLaboratoire Hubert Curien · FR

Funding

Agence de la Biomédecine Agence de la BiomédecineAppel d'Offre Recherche et Greffe 2022 Appel d'Offre Recherche et Greffe 2022Fondation des Gueules Cassées Fondation des Gueules CasséesUnion des Blessés de la Face et de la Tête (UBFT) Union des Blessés de la Face et de la Tête (UBFT)
6 · The paper itself

Abstract

The bioengineering of corneal endothelial grafts consists of seeding in vitro cultured corneal endothelial cells onto a thin, transparent, biocompatible, and sufficiently robust carrier which can withstand surgical manipulations. This is one of the most realistic alternatives to donor corneas, which are in chronic global shortage. The anterior capsule of the crystalline lens has already been identified as one of the best possible carriers, but its challenging manual preparation has limited its use. In this study, we describe a femtosecond laser cutting process of the anterior capsule of whole lenses in order to obtain capsule discs of 8 mm diameter, similar to conventional endothelial grafts. Circular marks made on the periphery of the disc indicate its orientation. Immersion in water for 3 days is sufficient to completely remove the lens epithelial cells and to enable the seeding of corneal endothelial cells, which remain viable after 27 days of culture. Therefore, this method provides a transparent, decellularized disc ready to form viable tissue engineered endothelial grafts.

Indexed as

corneal bioengineeringdecellularizationfemtosecond laserhuman anterior lens capsuleviable tissue-engineered endothelial keratoplasty

Identifiers

PMID38534529
PMCPMC10968626
OpenAlexW4392454077

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.