Evidence map›Paper›PMID 38534108›Full record

ArticleJournal of clinical microbiology2024

Sensitivity and specificity of the new Bio-Rad HIV screening test, Access HIV combo V2.

Vincent Guiraud, Yann Ciczora, Muriel Cardona, Christine Defer, Sandrine Gréaume, David Nogues, Agnès Gautheret-Dejean

Open access · hybridAbstract readEvaluation Study
In one paragraph

Article in Journal of clinical microbiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Analytical and Clinical Performance of VIDASDiagnostics (Basel, Switzerland) · 2026
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 1 country.

Vincent GuiraudAP-HP, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Service de Virologie, Paris, France.ORCID 0000-0002-4301-3771
Yann CiczoraBio-Rad Laboratories, Steenvoorde, France.
Muriel CardonaBio-Rad Laboratories, Marnes-La-Coquette, France.
Christine DeferEtablissement Français du Sang (EFS) Hauts de France-Normandie, Lille, France.
Sandrine GréaumeEtablissement Français du Sang (EFS) Hauts de France-Normandie, Bois-Guillaume, France.
David NoguesBio-Rad Laboratories, Steenvoorde, France.
Agnès Gautheret-DejeanAP-HP, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Service de Virologie, Paris, France.ORCID 0000-0003-0048-0318
Bio-Rad (France) · FRÉtablissement Français du Sang · FRInserm · FRSorbonne Université · FR

Funding

Bio-Rad Laboratories (Bio-Rad) No specific grant
6 · The paper itself

Abstract

Diagnosing of human immunodeficiency virus (HIV) types 1 and 2 requires a screening with a highly sensitive and specific enzyme immunoassay and a low detection limit for the HIV-1 p24 antigen to minimize the diagnostic window. The objective of the study was to determine the sensitivity, specificity, and p24 limit of detection of the Access HIV combo V2 assay. Retrospective part of sensitivity: 452 HIV-1 positive samples from 403 chronic (9 different HIV-1 group M subtypes, 22 different HIV-1 group M CRFs, and 3 HIV-1 group O), 49 primary HIV-1 infections, 103 HIV-2 positive samples assessed at Pitié-Salpêtrière Hospital, 600 untyped HIV-1, 10 subtype-D, and 159 untyped HIV-2 samples assessed in Bio-Rad Laboratories. Prospective part of clinical specificity: all consecutive samples in two blood donor facilities and Pitié-Salpêtrière (6,570 patients) tested with Access HIV combo V2 and respectively Prism HIV O Plus (Abbott) or Architect HIV Ag/Ab Combo (Abbott) for Ag/Ab screening, and Procleix Ultrio (Gen Probe) for HIV RNA screening. Limit of detection for p24 antigen was assessed on recombinant virus-like particles (10 HIV-1 group M subtypes/CRFs, HIV-1 group O). Sensitivity [95% confidence interval (CI)] of Access HIV combo V2 was 100% (99.63-100) for HIV-1 chronic infection, 100% (98.55-100) for HIV-2 chronic infection, and 100% (93.00-100) for HIV-1 primary infection. Specificity (95% CI) was 99.98 (99.91-100). Limit of detection for p24 antigen was around 0.43 IU/mL [interquartile range (0.38-0.56)], and consistent across the 11 analyzed subtypes/CRFs. Hence, with both high sensitivity and specificity, Access HIV combo V2 is a suitable screening assay for HIV-1/2 infection. IMPORTANCE: Bio-Rad is one of the leading human immunodeficiency virus (HIV) screening test manufacturers. This laboratory released in 2021 their new version of the Access combo HIV test. However, to date, there have been no studies regarding its performance, especially its limit of detection of the diverse p24 antigen. We present the sensitivity (chronic and primary HIV-1 infection and HIV-2 chronic infection), specificity (blood donors and hospitalized patients), and raw data for the p24/seroconversion panels the manufacturer gave to the European agencies.

Indexed as

HIV-1HIV-2HIV Core Protein p24HIV InfectionsMass ScreeningSensitivity and SpecificityHIV TestingHumansMaleProspective StudiesRetrospective StudiesHIV Core Protein p24Access HIV combo V2accuracyHIVsensitivityserologyspecificity

Identifiers

PMID38534108
PMCPMC11077987
OpenAlexW4393223332

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.