Evidence map›Paper›PMID 38533045›Full record

ArticleHeliyon2024

A continuous cuffless blood pressure measurement from optimal PPG characteristic features using machine learning algorithms.

Araf Nishan, S M Taslim Uddin Raju, Md Imran Hossain, Safin Ahmed Dipto, S M Tanvir Uddin, Asif Sijan, Md Abu Shahid Chowdhury, Ashfaq Ahmad, Md Mahamudul Hasan Khan

Abstract read
In one paragraph

Article in Heliyon, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Araf NishanDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
S M Taslim Uddin RajuDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
Md Imran HossainDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
Safin Ahmed DiptoDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
S M Tanvir UddinDepartment of Electrical and Electronic Engineering, Dhaka University of Engineering & Technology, Gazipur, Bangladesh.
Asif SijanDepartment of Software Engineering, American International University, Dhaka, Bangladesh.
Md Abu Shahid ChowdhuryDepartment of Biomedical Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
Ashfaq AhmadDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.
Md Mahamudul Hasan KhanDepartment of Computer Science and Engineering, Khulna University of Engineering & Technology, Khulna - 9203, Bangladesh.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and objective: Hypertension is a potentially dangerous health condition that can be detected by measuring blood pressure (BP). Blood pressure monitoring and measurement are essential for preventing and treating cardiovascular diseases. Cuff-based devices, on the other hand, are uncomfortable and prevent continuous BP measurement. Methods: In this study, a new non-invasive and cuff-less method for estimating Systolic Blood Pressure (SBP), Mean Arterial Pressure (MAP), and Diastolic Blood Pressure (DBP) has been proposed using characteristic features of photoplethysmogram (PPG) signals and nonlinear regression algorithms. PPG signals were collected from 219 participants, which were then subjected to preprocessing and feature extraction steps. Analyzing PPG and its derivative signals, a total of 46 time, frequency, and time-frequency domain features were extracted. In addition, the age and gender of each subject were also included as features. Further, correlation-based feature selection (CFS) and Relief F feature selection (ReliefF) techniques were used to select the relevant features and reduce the possibility of over-fitting the models. Finally, support vector regression (SVR), K-nearest neighbour regression (KNR), decision tree regression (DTR), and random forest regression (RFR) were established to develop the BP estimation model. Regression models were trained and evaluated on all features as well as selected features. The best regression models for SBP, MAP, and DBP estimations were selected separately. Results: The SVR model, along with the ReliefF-based feature selection algorithm, outperforms other algorithms in estimating the SBP, MAP, and DBP with the mean absolute error of 2.49, 1.62 and 1.43 mmHg, respectively. The proposed method meets the Advancement of Medical Instrumentation standard for BP estimations. Based on the British Hypertension Society standard, the results also fall within Grade A for SBP, MAP, and DBP. Conclusion: The findings show that the method can be used to estimate blood pressure non-invasively, without using a cuff or calibration, and only by utilizing the PPG signal characteristic features.

Indexed as

Continuous blood pressure (BP)Feature extractionFeature selectionNonlinear regression modelsPhotoplethysmogram (PPG)

Identifiers

PMID38533045
PMCPMC10963242

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.