Evidence map›Paper›PMID 38532875›Full record

ArticleFrontiers in bioengineering and biotechnology2024

PIV-MyoMonitor: an accessible particle image velocimetry-based software tool for advanced contractility assessment of cardiac organoids.

Hoyeon Lee, Boyoung Kim, Jiyue Yun, Jinseung Bae, Sungsu Park, Junseok Jeon, Hye Ryoun Jang, Jaecheol Lee, Soah Lee

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
5.2field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Hoyeon LeeDepartment of Biopharmaceutical Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Boyoung KimDepartment of Biopharmaceutical Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Jiyue YunDepartment of Biopharmaceutical Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Jinseung BaeSchool of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
Sungsu ParkSchool of Mechanical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.
Junseok JeonDivision of Nephrology, Department of Medicine, Cell and Gene Therapy Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Hye Ryoun JangDivision of Nephrology, Department of Medicine, Cell and Gene Therapy Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Jaecheol LeeDepartment of Biopharmaceutical Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Soah LeeDepartment of Biopharmaceutical Convergence, Sungkyunkwan University, Suwon, Republic of Korea.
Sungkyunkwan University · KRSamsung Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Induced pluripotent stem cell (iPSC)-derived cardiac organoids offer a versatile platform for personalized cardiac toxicity assessment, drug screening, disease modeling, and regenerative therapies. While previous image-based contractility analysis techniques allowed the assessment of contractility of two-dimensional cardiac models, they face limitations, including encountering high noise levels when applied to three-dimensional organoid models and requiring expensive equipment. Additionally, they offer fewer functional parameters compared to commercial software. To address these challenges, we developed an open-source, particle image velocimetry-based software (PIV-MyoMonitor) and demonstrated its capacity for accurate contractility analysis in both two- and three-dimensional cardiac models using standard lab equipment. Comparisons with four other open-source software programs highlighted the capability of PIV-MyoMonitor for more comprehensive quantitative analysis, providing 22 functional parameters and enhanced video outputs. We showcased its applicability in drug screening by characterizing the response of cardiac organoids to a known isotropic drug, isoprenaline. In sum, PIV-MyoMonitor enables reliable contractility assessment across various cardiac models without costly equipment or software. We believe this software will benefit a broader scientific community.

Indexed as

cardiac modelscontractilityinduced pluripotent stem cellsIPSC-CM cardiomyocytesorganoidparticle image velocimetry

Identifiers

PMID38532875
PMCPMC10964252
OpenAlexW4392715527

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.