Evidence map›Paper›PMID 38532766›Full record

ArticleOrthopaedic journal of sports medicine2024

Comparison of Time-Zero Primary Stability Between a Biodegradable Magnesium Bone Staple and Metal Bone Staples for Knee Ligament Fixation: A Biomechanical Study in a Porcine Model.

Adrian Deichsel, Johannes Glasbrenner, Michael J Raschke, Matthias Klimek, Christian Peez, Thorben Briese, Elmar Herbst, Christoph Kittl

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Adrian DeichselDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Johannes GlasbrennerDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Michael J RaschkeDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Matthias KlimekDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Christian PeezDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Thorben BrieseDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Elmar HerbstDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
Christoph KittlDepartment of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany.
University Hospital Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Bone staples have been shown previously to be a viable modality for cortical tendon graft fixation in ligament knee surgery. However, soft tissue reactions have been reported, making implant removal necessary. Magnesium alloys are a promising material for biodegradable orthopaedic implants, with mechanical properties closely resembling those of human bone. Purpose: To compare the primary stability of a biodegradable bone staple prototype made from magnesium to bone staples made from metal in the cortical fixation of tendon grafts during knee surgery. Study Design: Controlled laboratory study. Methods: Primary stability of peripheral tendon graft fixation was assessed in a porcine model of medial collateral ligament reconstruction. Two commercially available metal bone staples (Richards fixation staple with spikes [Me1] and spiked ligament staple [Me2]) were compared with a magnesium bone staple prototype for soft tissue fixation. Primary stability was assessed using a uniaxial materials testing machine. Cyclic loading at 50 and 100 N was applied for 500 cycles each, followed by load-to-failure testing. Results: After 500 cycles at 50 N, elongation was 1.5 ± 0.5 mm in the Me1 group, 1.9 ± 0.5 mm in the Me2 group, and 1.8 ± 0.4 mm in the magnesium group. After 1000 cycles of loading (500 cycles at 50 N and 500 at 100 N), elongation was 3.6 ± 0.9 mm in the Me1 group, 3.5 ± 0.6 mm in the Me2 group, and 4.1 ± 1.0 mm in the magnesium group. No significant differences regarding elongation were found between the groups. Load to failure was 352 ± 115 N in the Me1 group, 373 ± 77 N in the Me2 group, and 449 ± 92 N in the magnesium group, with no significant difference between the groups. Conclusion: In this study, the magnesium bone staples provided appropriate time-zero biomechanical primary stability in comparison with metal bone staples and may therefore be a feasible alternative for cortical fixation of tendon grafts in knee surgery. Clinical Relevance: The biodegradability of magnesium bone staples would eliminate the need for later implant removal.

Indexed as

biomechanicsbone staplescortical fixationligament reconstructionmagnesium

Identifiers

PMID38532766
PMCPMC10964459
OpenAlexW4393151799