Evidence map›Paper›PMID 38532601›Full record

ArticleRecent patents on nanotechnology2025

A Detailed Study on using Novel LM 25 Aluminium Alloy Hybrid Metal Matrix Nanocomposite for Nuclear Applications.

S C V Ramana Murty Naidu, Suresh Vellingiri, Paulraj Prabhu, Beporam Iftekhar Hussain, Abdul Rab Asary, Govindarajulu Padmanaban, Mukuloth Srinivasnaik, Kunnathur Periyasamy Yuvaraj

Abstract read
PubMed Publisher
In one paragraph

Article in Recent patents on nanotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 7 institutions in 2 countries.

S C V Ramana Murty NaiduDepartment of Mechanical Engineering, Sri Venkateswara College of Engineering and Technology, Eetcherla, Srikakulam, 532410, Andhra Pradesh, India.
Suresh VellingiriDepartment of Mechanical Engineering, KIT-Kalaignarkarunanidhi Institute of Technology, Coimbatore, 641 402, Tamil Nadu, India.ORCID 0000-0002-3993-4260
Paulraj PrabhuDepartment of Mechanical Engineering, KIT-Kalaignarkarunanidhi Institute of Technology, Coimbatore, 641 402, Tamil Nadu, India.
Beporam Iftekhar HussainDepartment of Mechanical Engineering, Bapatla Engineering College, Bapatla, 522102, Andhra Pradesh, India.
Abdul Rab AsaryDepartment of Energy Science and Engineering, University of Naples, Parthenope, Italy.
Govindarajulu PadmanabanDepartment of Mechanical Engineering, Karpagam College of Engineering, Coimbatore, Tamil Nadu, India.
Mukuloth SrinivasnaikDepartment of Mechanical Enginnering, School of Engineering, Jawaharlal Nehru University (JNU), New Delhi, 110067, India.
Kunnathur Periyasamy YuvarajDepartment of Mechanical Engineering, Sri Krishna College of Engineering and Technology, Coimbatore, Tamil Nadu, India.
PSG INSTITUTE OF TECHNOLOGY AND APPLIED RESEARCH · INHindu College of Pharmacy · INJawaharlal Nehru University · INKarpagam Academy of Higher Education · INKPR Institute of Engineering and Technology · INParthenope University of Naples · ITSri Venkateswara Veterinary University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThis article describes the use of graphite (Gr) and boron carbide (B4C) as multiple nanoparticle reinforcements in LM25 aluminum alloy. Because boron carbide naturally absorbs neutron radiation, aluminium alloy reinforced with boron carbide metal matrix composite has gained interest in nuclear shielding applications. The primary goal of the endeavor is to create composite materials with high wear resistance, high microhardness, and high ultimate tensile strength for use in nuclear applications. Patents on Gr and B4C can cover a wide range of subjects, including the synthesis and production methods of structural, armor materials, abrasives, and nuclear shielding.

backgroundScience and Technology have brought a vast change to human life. The human burden has been minimized by the use of innovation in developing new and innovative technologies. To improve the quality of human life, fresh, lightweight, and creative materials are being used, which play a vital role in science and technology and reduce the human workload. Composite materials made of metal are being used because they are lightweight. Neutron absorption, high ultimate strength, high wear resistance, high microhardness, high thermal and electrical conductivity, high vacuum environmental resistance, and low coefficient of thermal expansion under static and dynamic conditions are all demands for the hybrid metal matrix composites utilized in nuclear applications.

objectiveStir casting is used to create the novel LM 25 aluminum alloy/graphite and boron carbide hybrid nanocomposites. The mechanical properties such as ultimate tensile strength, yield strength, percentage of elongation, microhardness, and wear behavior are calculated. Three analyses are performed: microstructure, worn surface analysis, and fracture analysis of the tensile specimen.

methods(1) Stir casting process. (2) Tensile, hardness, wear test. (3) Materials characterization - FESEM, optical microscopy, EDS.

resultsThe mechanical properties values are 308.76 MPa, 293.51 MPa, 7.8, 169.2 VHN, and 0.01854 mm3/m intended for ultimate tensile strength, yield strength, percentage of elongation, microhardness, and wear behavior, respectively. This implies that the synthesized composite may be used in nuclear applications successfully.

conclusionThe subsequent explanation was drawn from this investigative work: The LM 25/B4C/Gr hybrid nanocomposite was successfully manufactured by employing the stir casting technique. For nuclear shielding applications, these composites were prepared with three different weight percentages of nanoparticle reinforcements in 2,4,6% Boron carbide and constant 4 wt.% graphite. The microhardness values of the three-hybrid nanocomposite fabricated castings were determined to be 143.4VHN, 156.7VHN, and 169.2VHN, respectively. The hybrid nano composite's microstructure revealed that the underlying LM 25 aluminum alloy matrix's finegrained, evenly dispersed nanoparticles of graphite and boron carbide were present. The microtensile test was carried out and it was found that the ultimate tensile strength, yield strength and percentage of elongation values are 281.35MPa, 296.52MPa, 308.76MPa, 269.43, 274.69, 293.51 and 3.4, 5.7, 7.8 respectively. Deformation caused the hybrid LM 25/B4C/Gr nanocomposite to fracture in ductile mode. Dimples and cavities are seen in the fracture because of the nanoparticle reinforcements and the matrix's tight connection. The wear loss of nanocomposite based on the input parameter applied load, sliding velocity and sliding distance values are 0.02456, 0.02189, 0.01854, 0.02892, 0.02586, 0.02315 and 0.02682, 0.02254, 0.02015 mm

Indexed as

EDS.microhardnessNano compositeneutron absorptionultimate tensile strengthyield strength

Identifiers

PMID38532601
OpenAlexW4393314659

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.