Evidence map›Paper›PMID 38532441›Full record

ArticleJournal of orthopaedic surgery and research2024

Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis.

Zhaokui Yan, Chang Zou, Guy Romeo Kenmegne, Xuelin Pan, Nawin Ghimire, Kuruwitage Manthi Nihara Silva, Yue Fang

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Zhaokui Yan *Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
Chang Zou *Department of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
Guy Romeo KenmegneDepartment of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
Xuelin PanDepartment of Radiology, West China Hospital of Sichuan University, Chengdu, 610041, China.
Nawin GhimireDepartment of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
Kuruwitage Manthi Nihara SilvaDepartment of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China.
Yue FangDepartment of Orthopedics, West China Hospital of Sichuan University, Chengdu, 610041, China. fangyue1968@163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study investigated the biomechanical properties of a new plate used for the treatment of posterolateral tibial plateau fractures using finite element analysis.

methodsThe study groups were as follows: group PM, model of the new plate with posteromedial tibial plateau fracture; group PL, model of the new plate with posterolateral tibial plateau fracture; and group PC, model of the new plate with posterior tibial plateau fracture. We used two loading modes: uniform loading on the entire plateau, and loading on the posterior plateau. Data such as the displacement of the fracture and distribution of stress on the new plate and screws were recorded and analyzed.

resultsWhen the whole plateau was loaded, the displacement of fractures in groups PM, PL, and PC were 0.273, 0.114, and 0.265 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 118.131 MPa, 44.191 MPa, and 115.433 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 166.731, 80.330, and 164.439 MPa, respectively. When the posterior tibial plateau was loaded, the displacement of the fractures in groups PM, PL, and PC was 0.410, 0.213, and 0.390 mm, respectively. The maximum stresses on the plates in groups PM, PL, and PC were 194.012 MPa, 72.806 MPa, and 185.535 MPa. The maximum stresses on the screws in Groups PM, PL, and PC were 278.265, 114.839, and 266.396 MPa, respectively.

conclusionThe results of this study revealed that titanium plates have good fixation effects in all groups; therefore, the use of the new plate for posterolateral tibial plateau fractures appears to be safe and valid.

Indexed as

Tibial FracturesTibial Plateau FracturesBiomechanical PhenomenaBone PlatesFinite Element AnalysisFracture Fixation, InternalHumansTibiaFinite-element analysisInternal fixationNew plateOsteosynthesisPosterolateralTibial plateau fracture

Identifiers

PMID38532441
PMCPMC10964653

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked