Evidence map›Paper›PMID 38532344›Full record

ArticleBMC anesthesiology2024

The effects of an IV fluid bolus on mitral annular velocity and the assessment of diastolic function: a prospective non-randomized study.

Sebastian Ayala, Orode Badakhsh, David Li, Neal W Fleming

Abstract read
In one paragraph

Article in BMC anesthesiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Sebastian AyalaDepartment of Anesthesiology & Pain Medicine, University of California, Davis, 4150 V Street Suite 1200 PSSB, Sacramento, CA, 95817, USA.
Orode BadakhshDepartment of Anesthesiology & Pain Medicine, University of California, Davis, 4150 V Street Suite 1200 PSSB, Sacramento, CA, 95817, USA.
David LiDepartment of Anesthesiology & Pain Medicine, University of California, Davis, 4150 V Street Suite 1200 PSSB, Sacramento, CA, 95817, USA.
Neal W FlemingDepartment of Anesthesiology & Pain Medicine, University of California, Davis, 4150 V Street Suite 1200 PSSB, Sacramento, CA, 95817, USA. nwfleming@ucdavis.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAbnormal diastolic function is an independent predictor of adverse postoperative outcomes. Mitral annular tissue Doppler velocity (e') is a key parameter for assessing diastolic function. The purpose of this study was to confirm that an acute increase in preload did not significantly impact the intraoperative measurement of e' and secondarily evaluate the impact of this acute intravascular volume increase on the clinical assessment of diastolic function using a previously described simplified algorithm.

methodsThis was a prospective, non-randomized study in adult patients undergoing elective cardiac surgeries requiring transesophageal echocardiographic monitoring, arterial pressure and Swan-Ganz catheter placements as part of the surgical procedure. Following baseline echocardiographic and hemodynamic measurements, 500 ml of crystalloid solution was infused over 10 min. Hemodynamic and echocardiographic measurements were repeated 5 min after fluid administration.

resultsComplete data sets were available from 84 of the 100 patients who were enrolled in this study. There was no significant change in the values of e'. The average baseline was 7.8 ± 2.0 cm/s (95%CI: 7.4, 8.2) and 8.1 ± 2.4 (95%CI: 7.6, 8.6) following the fluid bolus (p = 0.10). All hemodynamic variables associated with increased intravascular volume (central venous pressure, pulmonary arterial pressures and stroke volume variation) changed significantly. The overall distribution of diastolic function grades did not change following fluid administration (p = 0.69). However, there were many individual patient differences. When using this simplified algorithm, functional grading changed in 35 patients. Thirty of these 35 changes were only a single grade shift. 22 patients had worse functional grading after fluid administration while 13 had improved grading. Nine patients with normal diastolic function at baseline demonstrated diastolic dysfunction after fluid administration while 6 patients with baseline dysfunction normalized following the fluid bolus.

conclusionWe confirmed that e' is a robust measurement that is reproducible in the intraoperative setting despite variable vascular volume loading conditions, however, the clinical assessment of diastolic function was still altered in 42% of the patients following an intravenous fluid bolus.

Indexed as

Mitral ValveVentricular Dysfunction, LeftAdultDiastoleEchocardiographyHemodynamicsHumansProspective StudiesDiastolic dysfunctionIntravascular volumeMitral annular tissue velocity (e’)

Identifiers

PMID38532344
PMCPMC10964498

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.