Evidence map›Paper›PMID 38532018›Full record

ArticleScientific reports2024

Evaluation of the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble and its influence on dose.

Changhwan Kim, Hojae Kim, Dongmin Jung, Heesoo Kim, Yeonok Park, Min Cheol Han, Chae-Seon Hong, Hojin Kim, Ho Lee, Jinsil Sung and 2 more

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Changhwan KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Hojae KimDepartment of Radiation Oncology, Yonsei Cancer Center, Seoul, South Korea.
Dongmin JungDepartment of Radiation Oncology, Yonsei Cancer Center, Seoul, South Korea.
Heesoo KimDepartment of Radiation Oncology, Yonsei Cancer Center, Seoul, South Korea.
Yeonok ParkDepartment of Radiation Oncology, National Cancer Center, Proton Therapy Center, Goyang, South Korea.
Min Cheol HanDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Chae-Seon HongDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Hojin KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Ho LeeDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Jinsil SungDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea.
Dong Wook KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea. KDW1026@yuhs.ac.
Jin Sung KimDepartment of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, South Korea. JINSUNG@yuhs.ac.

Funding

Korea Foundation of Nuclear Safety 2205013-0122-CG100National Research Foundation of Korea 2022R1I1A1A01068163National Research Foundation of Korea RS-2022-00144201
6 · The paper itself

Abstract

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.

Indexed as

Radiotherapy, ConformalRadiotherapy, Intensity-ModulatedHumansParticle AcceleratorsRadiometryRadiotherapy DosageRadiotherapy Planning, Computer-Assisted

Identifiers

PMID38532018
PMCPMC10965989

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.