Evidence map›Paper›PMID 38530402›Full record

ArticleACS applied materials & interfaces2024

Sandwich Immuno-RCA Assay with Single Molecule Counting Readout: The Importance of Biointerface Design.

Katharina Schmidt, Tomas Riedel, Andres de Los Santos Pereira, N Scott Lynn, Diego Fernando Dorado Daza, Jakub Dostalek

Abstract read
In one paragraph

Article in ACS applied materials & interfaces, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Katharina SchmidtLaboratory for Life Sciences and Technology (LiST), Danube Private University, Viktor-Kaplan-Straße 2, 2700 Wiener, Neustadt, Austria.
Tomas RiedelInstitute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, Prague 162 00, Czech Republic.
Andres de Los Santos PereiraInstitute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, Prague 162 00, Czech Republic.
N Scott LynnFZU-Institute of Physics, Czech Academy of Sciences, Na Slovance 2, Prague 182 21, Czech Republic.
Diego Fernando Dorado DazaInstitute of Macromolecular Chemistry, Czech Academy of Sciences, Heyrovského nám. 2, Prague 162 00, Czech Republic.
Jakub DostalekLaboratory for Life Sciences and Technology (LiST), Danube Private University, Viktor-Kaplan-Straße 2, 2700 Wiener, Neustadt, Austria.ORCID 0000-0002-0431-2170

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The analysis of low-abundance protein molecules in human serum is reported based on counting of the individual affinity-captured analyte on a solid sensor surface, yielding a readout format similar to digital assays. In this approach, a sandwich immunoassay with rolling circle amplification (RCA) is used for single molecule detection (SMD) through associating the target analyte with spatially distinct bright spots observed by fluorescence microscopy. The unspecific interaction of the target analyte and other immunoassay constituents with the sensor surface is of particular interest in this work, as it ultimately limits the performance of this assay. It is minimized by the design of the respective biointerface and thiol self-assembled monolayer with oligoethylene (OEG) head groups, and a poly[oligo(ethylene glycol) methacrylate] (pHOEGMA) antifouling polymer brush was used for the immobilization of the capture antibody (cAb) on the sensor surface. The assay relying on fluorescent postlabeling of long single-stranded DNA that are grafted from the detection antibody (dAb) by RCA was established with the help of combined surface plasmon resonance and surface plasmon-enhanced fluorescence monitoring of reaction kinetics. These techniques were employed for in situ measurements of conjugating of cAb to the sensor surface, tagging of short single-stranded DNA to dAb, affinity capture of the target analyte from the analyzed liquid sample, and the fluorescence readout of the RCA product. Through mitigation of adsorption of nontarget molecules on the sensor surface by tailoring of the antifouling biointerface, optimizing conjugation chemistry, and by implementing weak Coulombic repelling between dAb and the sensor surface, the limit of detection (LOD) of the assay was substantially improved. For the chosen interleukin-6 biomarker, SMD assay with LOD at a concentration of 4.3 fM was achieved for model (spiked) samples, and validation of the ability of detection of standard human serum samples is demonstrated.

Indexed as

DNA, Single-StrandedSurface Plasmon ResonanceHumansDNA, Single-Strandedantifouling biointerfacebiomarkerdigital readout of assayrolling circle amplificationsingle molecule detectionsurface plasmon-enhanced fluorescencesurface plasmon resonance

Identifiers

PMID38530402
PMCPMC11009916

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.