Evidence map›Paper›PMID 38529520›Full record

ArticleJournal of industrial textiles2023

Toward the future of firefighter gear: Assessing fluorinated and non-fluorinated outer shells following simulated on-the-job exposures.

Nur-Us-Shafa Mazumder, Jingtian Lu, Andrew Stephen Hall, Arash Kasebi, Arjunsing Girase, Farzaneh Masoud, Jeffrey O Stull, R Bryan Ormond

Abstract read
In one paragraph

Article in Journal of industrial textiles, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Nur-Us-Shafa MazumderTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.ORCID 0000-0001-9591-8786
Jingtian LuTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.ORCID 0009-0006-8240-7411
Andrew Stephen HallTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.
Arash KasebiTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.ORCID 0000-0001-9156-9267
Arjunsing GiraseTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.ORCID 0000-0001-7707-5447
Farzaneh MasoudIllinois Fire Service Institute, University of Illinois at Urbana Champaign, Champaign, IL, USA.
Jeffrey O StullInternational Personnel Protection, Inc, Austin, TX, USA.
R Bryan OrmondTextile Protection and Comfort Center, Wilson College of Textiles, North Carolina State University, Raleigh, NC, USA.ORCID 0000-0001-9799-546X

Funding

DHS DHS999999
6 · The paper itself

Abstract

In 2022, the occupation of firefighting was categorized as a "Group 1" carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids. The PFAS-based aqueous emulsion typically used in DWR finishes is highly persistent and can cause various health problems if absorbed into the body through ingestion, inhalation, and/or dermal absorption. In response, the U.S. Fire Service has begun using non-PFAS water repellants in firefighter turnout gear. This study aims to evaluate the performance of both traditional PFAS-based and alternative non-PFAS outer shell materials. The study involved exposing both PFAS-based and non-PFAS DWR outer shell materials in turnout composites to simulated job exposures (i.e., weathering, thermal exposure, and laundering) that artificially aged the materials. After exposures, samples were evaluated for repellency, durability, thermal protection, and surface chemistry analysis to determine any potential performance trade-offs that may exist. Non-PFAS outer shell fabrics were found not to be diesel/oil-repellent, posing a potential flammability hazard if exposed to diesel and subsequent flame on an emergency response. Both PFAS-based and non-PFAS sets of fabrics performed similarly in terms of thermal protective performance, tearing strength, and water repellency. The surface analysis suggests that both PFAS and non-PFAS chemistries can degrade and shed from fabrics during the aging process. The study indicates that firefighters should be educated and trained regarding the potential performance trade-offs, such as oil absorption and flammability concerns when transitioning to non-PFAS outer shell materials.

Indexed as

AgingDWRFirefightersouter shellPFASturnout gear

Identifiers

PMID38529520
PMCPMC10962281

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked