Evidence map›Paper›PMID 38528938›Full record

ArticleJournal of ultrasonography2024

Real-time ultrasound-guided thoracentesis simulation using an optical see-through head-mounted display: a proof-of-concept study.

Shotaro Okachi, Toshinori Matsui, Manami Sakurai, Takayasu Ito, Masahiro Morise, Kazuyoshi Imaizumi, Makoto Ishii, Michitaka Fujiwara

Open access · diamondAbstract read
In one paragraph

Article in Journal of ultrasonography, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Shotaro OkachiDepartment of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0003-1869-7953
Toshinori MatsuiDepartment of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0009-0004-3873-5472
Manami SakuraiMedical xR Center, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0001-9882-9623
Takayasu ItoDepartment of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0003-1108-1574
Masahiro MoriseDepartment of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0001-6576-3349
Kazuyoshi ImaizumiDepartment of Respiratory Medicine, Fujita Health University School of Medicine, Toyoake, Japan.ORCID https://orcid.org/0000-0002-3790-8691
Makoto IshiiDepartment of Respiratory Medicine, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0003-4396-1664
Michitaka FujiwaraMedical xR Center, Nagoya University Graduate School of Medicine, Nagoya, Japan.ORCID https://orcid.org/0000-0002-7189-5580
Nagoya University · JPFujita Health University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aim: This study aimed to examine the feasibility and potential benefits of an optical see-through head-mounted display (OST-HMD) during real-time ultrasound-guided thoracentesis simulations. Material and methods: Six physicians performed a thoracentesis simulation using an OST-HMD and a wireless image transmission system. The time required, puncture needle visibility, pleural fluid collection success rate, and head movement during the procedure using a smart glass equipped with an inertial measurement unit were all recorded and compared with and without the HMD. Results: Study participants successfully extracted effusions in all procedures. The use of OST-HMD did not significantly affect the time of the procedure, but notably decreased the horizontal and vertical head movements during the procedure. Conclusions: The study demonstrated the feasibility of using an OST-HMD in a simulated real-time ultrasound-guided thoracentesis procedure and showed the potential of HMD in thoracentesis to improve ergonomics and accuracy. Further research is necessary to confirm these findings.

Indexed as

head-mounted displaypleural effusionthoracentesisultrasound

Identifiers

PMID38528938
PMCPMC10961472
OpenAlexW4393006152

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.