ArticleBehavior research methods2024

From lab to life: Evaluating the reliability and validity of psychophysiological data from wearable devices in laboratory and ambulatory settings.

Xin Hu, Tanika R Sgherza, Jessie B Nothrup, David M Fresco, Kristin Naragon-Gainey, Lauren M Bylsma

Abstract read
In one paragraph

Article in Behavior research methods, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xin HuDepartment of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
Tanika R SgherzaSchool of Psychological Science, University of Western Australia, Perth, Australia.
Jessie B NothrupDepartment of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA.
David M FrescoDepartment of Psychiatry, University of Michigan, Ann Arbor, MI, USA.
Kristin Naragon-GaineySchool of Psychological Science, University of Western Australia, Perth, Australia.
Lauren M BylsmaDepartment of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA, USA. bylsmal@pitt.edu.ORCID http://orcid.org/0000-0003-3828-1760

Funding

Emotion Regulation in Distress Disorders: Elucidating the Role of Cognitive Processes and Person-Situation Fit in the Laboratory and Daily LifeR01MH118218 · NIMH · UNIVERSITY OF WESTERN AUSTRALIA · PI GAINEY, KRISTIN · 2019 to 2023
$2.2M
Parent-Child Interaction and Emotion Regulation in Preschoolers with Autism Spectrum DisorderK23MH127420 · NIMH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI Jessie B Northrup · 2022 to 2026
$873k
NIMH NIH HHS K23 MH127420NIMH NIH HHS MH118218NIMH NIH HHS MH127420NIMH NIH HHS R01 MH118218
6 · The paper itself

Abstract

Despite the increasing popularity of ambulatory assessment, the reliability and validity of psychophysiological signals from wearable devices is unproven in daily life settings. We evaluated the reliability and validity of physiological signals (electrocardiogram, ECG; photoplethysmography, PPG; electrodermal activity, EDA) collected from two wearable devices (Movisens EcgMove4 and Empatica E4) in the lab (N = 67) and daily life (N = 20) among adults aged 18-64 with Mindware as the laboratory gold standard. Results revealed that both wearable devices' valid data rates in daily life were lower than in the laboratory (Movisens ECG 82.94 vs. 93.10%, Empatica PPG 8.79 vs. 26.14%, and Empatica EDA 41.16 vs. 42.67%, respectively). The poor valid data rates of Empatica PPG signals in the laboratory could be partially attributed to participants' hand movements (r = - .27, p = .03). In laboratory settings, heart rate (HR) derived from both wearable devices exhibited higher concurrent validity than heart rate variability (HRV) metrics (ICCs 0.98-1.00 vs. 0.75-0.97). The number of skin conductance responses (SCRs) derived from Empatica showed higher concurrent validity than skin conductance level (SCL, ICCs 0.38 vs. 0.09). Movisens EcgMove4 provided more reliable and valid HRV measurements than Empatica E4 in both laboratory (split-half reliability: 0.95-0.99 vs. 0.85-0.98; concurrent validity: 0.95-1.00 vs. 0.75-0.98; valid data rate: 93.10 vs. 26.14%) and ambulatory settings (split-half reliability: 0.99-1.00 vs. 0.89-0.98; valid data rate: 82.94 vs. 8.79%). Although the reliability and validity of wearable devices are improving, findings suggest researchers should select devices that yield consistently robust and valid data for their measures of interest.

Indexed as

ElectrocardiographyGalvanic Skin ResponseHeart RatePhotoplethysmographyWearable Electronic DevicesAdolescentAdultFemaleHumansMaleMiddle AgedMonitoring, AmbulatoryPsychophysiologyReproducibility of ResultsYoung AdultAmbulatory assessmentElectrodermal activityHeart rate variabilityReliabilityValidityWearable devices

Identifiers

PMID38528248
PMCPMC12403079

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.