Evidence map›Paper›PMID 38526773›Full record

ArticleGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2024

Tolerance to decentration of biaspheric intraocular lenses with refractive phase-ring extended depth of focus and diffractive trifocal designs.

Alejandro Cerviño, Jose Juan Esteve-Taboada, Yi-Feng Chiu, Chuan-Hui Yang, Wen-Chu Tseng, William Lee

Abstract read
In one paragraph

Article in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Alejandro CerviñoDepartment of Optics & Optometry & Vision Sciences, University of Valencia, C / Dr. Moliner, 50., 46100, Burjassot, Valencia, Spain. alejandro.cervino@uv.es.ORCID http://orcid.org/0000-0001-8014-3279
Jose Juan Esteve-TaboadaDepartment of Optics & Optometry & Vision Sciences, University of Valencia, C / Dr. Moliner, 50., 46100, Burjassot, Valencia, Spain.ORCID http://orcid.org/0000-0001-8663-6373
Yi-Feng ChiuICARES Medicus, Inc, Hsinchu County, Taiwan.
Chuan-Hui YangICARES Medicus, Inc, Hsinchu County, Taiwan.
Wen-Chu TsengICARES Medicus, Inc, Hsinchu County, Taiwan.
William LeeICARES Medicus, Inc, Hsinchu County, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aimed to investigate the in vitro tolerance to decentration of biaspheric intraocular lens (IOLs) with refractive phase-ring extended depth-of-focus (EDOF) and diffractive trifocal designs.

methodsThis experimental study was carried out at the Department of Optics and Optometry and Vision Science, University of Valencia, Spain. The modulation transfer function (MTF) of the ETLIO130C EDOF and the TFLIO130C trifocal IOLs (AST Products Inc., Billerica, MA, USA) were determined at different levels of decentration for a given wavelength and pupil diameter using the PMTF optical bench (Lambda-X Ophthalmics, Nivelles, Belgium). The modulation transfer function (MTF) curves, the through-focus MTF curves, and the Strehl ratios were measured at 3-mm pupil aperture for 0.25-, 0.50- and 0.75-mm decentration.

resultsThe optical design of the trifocal TFLIO130C IOL is robust to small decentrations, with virtually no change in MTF response for 0.25 mm decentration. For greater decentration levels, the MTF response is slightly reduced with increasing decentration. The ETLIO130C EDOF design is robust to decentration, as the MTF response is only minimally affected when increasing the decentration up to 0.75 mm.

conclusionsMTF responses are slightly reduced with greater levels of decentration, but the range of focus provided by both trifocal and EDOF designs are preserved. The effects for average levels of decentration reported in the literature are minimum for both IOL designs.

Indexed as

Prosthesis DesignRefraction, OcularArtificial Lens Implant MigrationDepth PerceptionHumansLenses, IntraocularMultifocal Intraocular LensesOptics and PhotonicsVisual AcuityEDOF IOLIn vitroOptical benchOptical qualityPresbyopia correcting IOLTrifocal IOL

Identifiers

PMID38526773
PMCPMC11271318

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.