ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2024
Off-label use of muscular VSD device for closure of a rare congenital portosystemic shunt.
Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCongenital portosystemic shunt (CPSS) is a vascular malformation in which portal blood drains toward the systemic circulation, leading to pulmonary hypertension. CASE PRESENTATION: A 10-year-old patient was brought for evaluation because of dyspnea on exertion. Echocardiography revealed a pulmonary hypertension of 75 mmHg, and multi-slice CT angiography revealed the presence of a CPSS. Closure was finally implemented using a muscular ventricular septal defect device. Follow-up of the patient revealed a gradual decline in pulmonary hypertension.
conclusionsCPSS is an overlooked cause of reversible pulmonary hypertension (PH). Closure of such lesions and reversal pulmonary hypertension are possible via catheterization. The preferred device type depends largely on the intervening team. Plugs are the first choice for interventional radiologists, while ventricular and atrial septal occluder devices and duct occluders are preferred by pediatric cardiologists.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.