In vitro hemodynamic performance of a blood pump for self-powered venous assist in univentricular hearts.

Reza Rasooli, Henrik Holmstrom, Knut Erik Teigen Giljarhus, Ingunn Westvik Jolma, Jan Ludvig Vinningland, Charlotte de Lange, Henrik Brun, Aksel Hiorth

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Technological evolution ofFrontiers in physiology · 2025
    Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 2 countries.

Reza RasooliDepartment of Energy Resources, Faculty of Science and Technology, University of Stavanger, 4036, Stavanger, Norway. reza.rasooli@uis.no.
Henrik HolmstromDepartment of Pediatric Cardiology, Division of Pediatric and Adolescent Medicine, Oslo University Hospital, Oslo, Norway.
Knut Erik Teigen GiljarhusDepartment of Mechanical and Structural Engineering and Materials Science, University of Stavanger, 4036, Stavanger, Norway.
Ingunn Westvik JolmaDepartment of Chemistry, Bioscience and Environmental Engineering, University of Stavanger, 4036, Stavanger, Norway.
Jan Ludvig VinninglandNorwegian Research Center (NORCE), Oslo, Norway.
Charlotte de LangeDepartment of Pediatric Radiology, Sahlgrenska University Hospital, Gothenburg, Sweden.
Henrik BrunDepartment of Pediatric Cardiology, Division of Pediatric and Adolescent Medicine, Oslo University Hospital, Oslo, Norway.
Aksel HiorthDepartment of Energy Resources, Faculty of Science and Technology, University of Stavanger, 4036, Stavanger, Norway.
University of Stavanger · NOOslo University Hospital · NONORCE Research AS · NOSahlgrenska University Hospital · SE

Funding

Equinor PR-10742
6 · The paper itself

Abstract

Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. An invitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% during full-assist mode. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.

Indexed as

Fontan ProcedureHeart Defects, CongenitalUniventricular HeartHeart VentriclesHemodynamicsHumansModels, CardiovascularPulmonary Artery

Identifiers

PMID38521832
PMCPMC10960831
OpenAlexW4393118558

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.