Mechatronic automatic control system of electropneumatic manipulator.

Olena Nazarova, Volodymyr Osadchyy, Taras Hutsol, Szymon Glowacki, Tomasz Nurek, Vadym Hulevskyi, Iryna Horetska

Abstract read
In one paragraph

Article in Scientific reports, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Olena NazarovaDepartment of Electric Drive and Automation of Industrial Equipment, Zaporizhzhia Polytechnic National University, Zhukovsky, 64, Zaporizhzhia, 69-063, Ukraine. nazarova16@gmal.com.
Volodymyr OsadchyyDepartment of Electric Drive and Automation of Industrial Equipment, Zaporizhzhia Polytechnic National University, Zhukovsky, 64, Zaporizhzhia, 69-063, Ukraine.
Taras HutsolDepartment of Mechanics and Agroecosystems Engineering, Polissia National University, Zhytomyr, 10-008, Ukraine. wte.inter@gmail.com.
Szymon GlowackiDepartment of Fundamentals of Engineering and Power Engineering, Institute of Mechanical Engineering, Warsaw University of Life Sciences-SGGW, 02-787, Warsaw, Poland. szymon_glowacki@sggw.edu.pl.
Tomasz NurekDepartment of Biosystem Engineering, Institute of Mechanical Engineering, Warsaw University of Life Sciences-SGGW, 02-787, Warsaw, Poland.
Vadym HulevskyiDepartment of Electric Power Engineering and Electrical Technologies, Faculty of Energy and Computer Technology, Dmytro Motornyi Tavria State Agrotechnological University, Melitopol, Ukraine.
Iryna HoretskaInnovative Program of Strategic Development of the University, European Social Fund, University of Agriculture in Krakow, 30-149, Kraków, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mechatronic systems of electropneumatic automation are one of the main classes of industrial automation systems. A laboratory stand for the study of the mechatronic system of automatic control of the pneumatic manipulator and a computer model for preliminary experiments on the adjustment of the automatic control system were developed. Manual and software control modes are provided for research of indicators of safety and quality of management in both modes. To implement the software control mode, a microcontroller part of the laboratory stand based on ADuC841 was developed, with the help of which it is possible to simulate a part of a certain technological process, to detect and eliminate faults in the automatic control system. A study of automatic control systems using a traditional relay-contactor control system, based on GrafCet technology and using a virtual controller. The combination of computer modeling of technological processes and physical modeling of executive mechanisms is a kind of digital double that displays its state, parameters and behavior in real time. The use of a laboratory stand in combination with an adequate simulation model reduces the complexity of developing control systems for practical applications, and also contributes to the formation of students' creative component, ability to analyze the results, and make decisions in unusual situations, which will increase their theoretical and practical training. The study of mechatronic systems of pneumatic manipulators will allow to increase their efficiency and productivity, to optimize their speed and accuracy for various applications in production. The interaction of mechatronic systems of pneumatic manipulators with other technologies, such as machine learning, artificial intelligence, IoT is the basis for creating more integrated and intelligent systems.