Evidence map›Paper›PMID 38520549›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Are silver-coated megaprostheses superior to uncoated megaprostheses in managing chronic end-stage periprosthetic hip and knee infection?

Matías Vicente, Josep Nomdedeu, Kushal Lakhani, Pablo S Corona

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matías VicenteSeptic and Reconstructive Surgery Unit, Orthopaedic Surgery Department, Vall d'Hebrón University Hospital, Universitat Autònoma de Barcelona, Pg. Vall d'Hebron 119-129, 08035, Barcelona, Spain. matias.vicente@vallhebron.cat.ORCID http://orcid.org/0000-0002-9404-9299
Josep NomdedeuOrthopaedic Surgery Department, Vall d'Hebron University Hospital, Universitat Autònoma de Barcelona, Barcelona, Spain.
Kushal LakhaniSeptic and Reconstructive Surgery Unit, Orthopaedic Surgery Department, Vall d'Hebrón University Hospital, Universitat Autònoma de Barcelona, Pg. Vall d'Hebron 119-129, 08035, Barcelona, Spain.
Pablo S CoronaSeptic and Reconstructive Surgery Unit, Orthopaedic Surgery Department, Vall d'Hebrón University Hospital, Universitat Autònoma de Barcelona, Pg. Vall d'Hebron 119-129, 08035, Barcelona, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionOutcomes for silver coated megaprostheses (SC-MP) used in cases of end-stage periprosthetic joint infection (PJI) have not been clearly defined. Although attractive, concerns over implant longevity and the risk of infection relapse exist among the scientific community. Therefore, we sought to investigate the effect of silver coating in lower-extremity MPs used in such difficult-to-treat scenarios. The study's primary hypothesis was that the periprosthetic infection control rate would be higher in patients with silver-coated implants. MATERIALS AND

methodsNon-interventional retrospective study with a historical comparison group. We identified all consecutive end-stage hip and knee PJI cases at our center managed with exchange arthroplasty using a silver-coated megaprosthesis from January 2016 to March 2021, these cases were compared with a historical cohort of end-stage PJI cases managed with uncoated megaprostheses. The main outcome studied was infection control rate. Secondarily, we analyzed the short-to-medium-term survivorship of this type of silver-coated implant.

resultsFifty-nine megaprostheses used in cases of end-stage PJI were included in this study. We identified 30 cases of chronic hip or knee PJI in which a silver-coated modular megaprosthesis was implanted. Our non-coated megaprosthesis (NC-MP) historical group included 29 patients. Both groups had similar demographic characteristics. We found no statistically significant differences in infection control rate (80% vs. 82.8%, p = 0.47) or implant survivorship (90% vs. 89.65%, p = 1) after a mean follow-up for SC-MP of 46.43 months, and 48 months for the non-coated MP group. In relapsed cases, there were no differences in infection eradication after DAIR (66% SC-MP vs. 60% NC-MP success rate, p = 1). During the follow-up we observed one case of skin argyria without further repercussion.

conclusionWe were unable to confirm our initial hypothesis that use of silver-coated implants in end-stage PJI scenarios may be associated with better outcomes in terms of infection control or implant survivorship.

Indexed as

Coated Materials, BiocompatibleHip ProsthesisKnee ProsthesisProsthesis-Related InfectionsSilverAgedAged, 80 and overArthroplasty, Replacement, HipArthroplasty, Replacement, KneeFemaleHumansMaleMiddle AgedProsthesis DesignRetrospective StudiesCoated Materials, BiocompatibleSilverEnd-stage periprosthetic infectionExchange arthroplastyMegaprosthesisPeriprosthetic joint infectionSilver-coated

Identifiers

PMID38520549

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked