Evidence map›Paper›PMID 38520547›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.

Stephen Warner, Christoph Sommer, Ivan Zderic, William Woodburn, Richard Castle, Jessica Penman, Eladio Saura-Sanchez, David L Helfet, Boyko Gueorguiev, Karl Stoffel

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.7field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 6 institutions in 3 countries.

Stephen WarnerUniversity of Texas Health Science Center, Houston, TX, USA.
Christoph SommerCantonal Hospital Graubünden, Chur, Switzerland.
Ivan ZdericAO Research Institute Davos, Davos, Switzerland. ivan.zderic@aofoundation.org.ORCID http://orcid.org/0000-0003-0484-887X
William WoodburnDePuy Synthes, West Chester, PA, USA.
Richard CastleDePuy Synthes, West Chester, PA, USA.
Jessica PenmanDePuy Synthes, West Chester, PA, USA.
Eladio Saura-SanchezUniversity Hospital of Elche, Elche, Spain.
David L HelfetNew York Presbyterian Hospital, New York Weill Cornell Center, New York, NYC, USA.
Boyko GueorguievAO Research Institute Davos, Davos, Switzerland.
Karl StoffelUniversity Hospital Basel, Basel, Switzerland.
AO Foundation · CHHospital General Universitario de Elche · ESKantonsspital Graubünden · CHNewYork–Presbyterian Hospital · USThe University of Texas Health Science Center at Houston · USUniversity Hospital of Basel · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionTreatment of both simple and complex patella fractures is a challenging clinical problem. Although tension band wiring has been the standard of care, it can be associated with high complication rates. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. MATERIALS AND

methodsSixteen pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34-C1 or five-part complex AO/OTA 34-C3 patella fractures by means of osteotomies, with each fracture model created in eight pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior (central distal) fragment mimicking comminution around the distal patellar pole. The specimens with simple fractures were pairwise assigned for fixation with either tension band wiring through two parallel cannulated screws or a lateral rim variable angle locking plate. The knees with complex fractures were pairwise treated with either tension band wiring through two parallel cannulated screws plus circumferential cerclage wiring or a lateral rim variable angle locking plate. Each specimen was tested over 5000 cycles by pulling on the quadriceps tendon, simulating active knee extension and passive knee flexion within the range of 90° flexion to full extension. Interfragmentary movements were captured via motion tracking.

resultsFor both fracture types, the articular displacements measured between the proximal and distal fragments at the central patella aspect between 1000 and 5000 cycles, together with the relative rotations of these fragments around the mediolateral axis were all significantly smaller following the lateral rim variable angle locked plating compared with tension band wiring, p ≤ 0.01.

conclusionsFrom a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.

Indexed as

Bone PlatesBone WiresFracture Fixation, InternalFractures, BonePatellaAgedBiomechanical PhenomenaCadaverFemaleHumansMalePatella FractureBiomechanicsComplex patella fractureLateral rim variable angle locked platingMotion trackingSimple patella fractureTension band wiring

Identifiers

PMID38520547
OpenAlexW4393115091

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.