ArticleJournal of cardiothoracic surgery2024
Investigation of the appropriate viscosity of fibrinogen in repairing pleural defects using ventilation and anchoring in an ex vivo pig model.
Article in Journal of cardiothoracic surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveOur previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model.
methodsThe fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N = 10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites.
resultsThe median rupture pressure was 51.5 (40-73) cmH2O in Group 1 (lower viscosity), 47.0 (47-88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25-61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group.
conclusionsThe results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials